PBPro-ETH

Remote PROFIBUS Interfaces for Use as Master or Slave

PBpro ETH is a family of interfaces for remote access to one, two, three or four PROFIBUS segments via Ethernet for device parameterization, controller programming and data acquisition. On the PC the remote interface acts like a local PROFIBUS board.

PBPro-ETH

Wide Range of Applications

  • De-facto standard for device parameterization via FDT/DTM
  • PROFIBUS connection for PC-based measuring and monitoring systems
  • External PROFIBUS interface for PC-based field devices and embedded computer systems
  • Quick and easy integration of OPC Client applications like SCADA or MES systems via optional OPC Server

Individual Protocol Settings for Each Channel

  • Access to process data and parameters in connected devices as PROFIBUS DP Master or Master Class 2 (also simultaneously with existing control systems)
  • Data exchange with controllers as PROFIBUS DP Slave
  • Integration into PROFIBUS FMS systems, or into proprietary applications via PROFIBUS FDL
  • Each channel acting as an individual PROFIBUS PC interface

Easy Administration and Efficient Integration

  • Assignment of IP address and configuration with accompanying “Search and Configure” tool and integrated web interface
  • Commented sample programs for easy use of the PROFIBUS application programming interface (API)
  • Free-of-charge communication DTM for PBpro ETH supporting parameterization of PROFIBUS devices by FDT tools
PBpro ETH
Single Channel
PBpro ETH
Dual Channel
PBpro ETH
Triple Channel
PBpro ETH
Quad Channel
Number of Channels 1 2 3 4
PROFIBUS Protocol 
DP-V0 Master All Channels All Channels All Channels
DP-V1 Master: Acyclic C2 Services All Channels All Channels All Channels
FMS All Channels All Channels All Channels
FDL All Channels All Channels All Channels
DP-V0 Slave Channel 2 Channel 2,3 Channel 2,3,4
Connector 9-pin D-Sub female, EIA-485 (RS-485), galvanically isolated
Transfer Rates 9.6; 19.2; 45.45; 93.75; 187.5; 500; 1500; 3000; 6000; 12000 Kbit/s
Host Interface
Ethernet 100BASE-TX/10BASE-T, 100 Mbit/s and 10 Mbit/s with automatic detection, RJ45 connector
Web Server For device status and configuration
Remote API Windows DLL for host computer
TCP/IP Socket Library Easily portable source code and programming samples for non-Windows computers
Miscellaneous
Mounting 35 mm DIN Rail
Dimensions (W x H x D) 47 mm x 131 mm x 111 mm 110 mm x 131 mm x 111 mm 110 mm x 131 mm x 111 mm 110 mm x 131 mm x 111 mm
Power Supply 24 VDC (±20%) Typically 0.2A 24 VDC (±20%) Typically 0.3A 24 VDC (±20%) Typically 0.4A 24 VDC (±20%) Typically 0.5A
Temperature Range 0 °C … +55 °C (Operation); -20 °C … +70 °C (Storage); fanless convection cooling
Relative Humidity < 90%, Non-Condensing
Protection Class IP20
Available Drivers Windows 2000, Windows XP, Windows Vista, Windows 7, Windows 8, Windows Server 2003 R2, Windows Server 2008
DEL-NN-012311 PBpro ETH; Single Channel
DEL-NN-012312 PBpro ETH; Dual Channel
DEL-NN-012313 PBpro ETH; Triple Channel
DEL-NN-012314 PBpro ETH; Quad Channel

Scope of Delivery

Hardware PROFIBUS Remote Interface
Software Windows Drivers, Sample Programs, PROFIdtm
Documentation User Guide

Additional Products and Services

OPC-PB PROFIBUS OPC Server for DP-V0 / DP-V1
DCF-DY-4100 OPC Server for S7 / S5
TRA-PB-TECH PROFIBUS Technology Training

mobiLink Interface

Mobile Interface for HART, FOUNDATION fieldbus, Profibus PA

csm_mobiLink_5ff21a0363

mobiLink is a both Bluetooth and USB solution for commissioning parameterization & maintenance for field devices

  • Single interface for the major Process Automation protocols: HART / Foundation fieldbus / PROFIBUS PA
  • Perfectly suited for handheld host devices due to battery powered Bluetooth operation
  • Compatible with FDT Frame Applications
  • Approved for use in hazardous areas

Multi protocol operation available on mobiLink

  • HART Master, Foundation fieldbus Host and PROFIBUS PA Master  included in one device
  • Temporary attachment to fieldbus segments or HART loops for individual interaction with field devices
  • Fully compliant protocol implementations allow for interference-free access to running plants

Host communication via Bluetooth or USB

  • Built-in batteries and Bluetooth communication enable use of handheld host devices like smart phones and tablets
  • USB interface for bench host operation

mobiLink support of FDT Frame Applications and major Engineering Tools

  • PACTware FDT Frame Application and HART Communication DTM included
  • Communication DTM for Foundation fieldbus and PROFIBUS PA (optional)
  • Foundation fieldbus configuration tool (optional)
  • Application Program Interface for integration into Engineering Systems

Suitable for use in hazardous areas

  • The mobiLink is EX approval for Zone 1
  • Suitable for connection to intrinsically safe circuits
  • Suited for harsh environment
User Interface Controls
Status LEDs
Power on/off button, Bluetooth pairing button
FIELDBUS (Fieldbus mode), HART (HART mode), Bluetooth (Pairing/Bluetooth active), Low battery, Power on
Interfaces and Connectors USB

Bluetooth

Fieldbus

HART

Speed: USB 2.0 Full Speed
Connector: USB Type C
Electrical: Non intrinsically safe. Do not use inside hazardous areas.
5V, 100mA. Um = 253VBT mode: BT Classic, 2.4 – 2.478 GHz Output Power: +8 dBm (maximum)Connection: 4 mm banana type jacks (red/black), polarity has to be observed
Physical Layer: according to IEC 61158-2, Type 1: 31.25 Kbit/s, voltage mode
Nominal input current (Fieldbus):
10 mA in Bluetooth and regular USB mode
18 mA (with Ufieldbus > 9,5V) for increased battery life time in USB mode (controlled by application)
Fieldbus Terminator: No fieldbus terminator includedConnection: 4 mm banana type jacks (red/black)
Physical Layer: HART FSK compliant modem
Operation in Hazardous Areas Intrinsic Safety Parameters EX ia IIB, Ui = 30 V or FISCO field device
Isolation: 1500 VDC between USB and Fieldbus, 1500 VDC between USB and HART
Physical Properties Dimensions (L x W x D)

Weight

Power Supply

Operating Temperature

Storage

Relative Humidity

Protection Class

175 mm x 74 mm x 32 mm

330 g (incl. Batteries)

Battery: 3 * Alkaline, IEC-LR6, nominal voltage 1,5V
For use in hazardous area: Energizer E91 or Duracell Procell MN1500.
With batteries of other types or manufacturers certification is void.
Fieldbus interface (Medium Attachment Unit) powered by fieldbus.

-20°C .. +50°C

Store batteries in a dry place at normal room temperature.

< 95% rH non condensing

IP 54 (if USB port covered with cap)

Scope of Delivery
Hardware mobiLink, USB cable, fieldbus cable set with clips, 3 * Alkaline IEC-LRC6, USB memory stick
Software PACTware, Communication DTM for HART, Foundation Fieldbus and PROFIBUS PA (for Foundation Fieldbus and PROFIBUS PA optional license required)
Foundation Fieldbus Configuration Tool ComConf (optional license required)
Documentation On USB memory stick
Order Numbers
DBA-KM-020410 mobiLink for HART applications
LRA-KK-021971 Licence for FF CommDTM
LRA-NN-021972 Licence for PA CommDTM
LRA-KK-020721 Licence for FF Configuration Tool ComConf
DBL-KM-020411 mobiLink HART incl. FF Comm DTM Licence
DBL-KM-020412 mobiLink HART incl. FF and PA Comm DTM Licenc

How to connect with Foundation Fieldbus devices via mobiLink:

How to connect with Foundation Fieldbus devices via mobiLink:

How to change Foundation Fieldbus node addresses:

People interested in this product, are also interested in :

PBpro-USB

PBPro-USB : PROFIBUS USB interface

PBPro-USB

Universal PROFIBUS Interface with USB High Speed

High performance PROFIBUS USB interface for a wide variety of tasks from network configuration and device parameterization to plant maintenance and production data acquisition.

Handy Companion for Mobile Use

  • Matchbox-sized PROFIBUS interface
  • Always at hand – easily fits in any laptop bag
  • High-retention USB connector ensures reliable USB cable connection

Wide Area of Application

  • Device parameterization via FDT/DTM
  • Integrated with numerous parameterization and asset management systems
  • PROFIBUS connection for PC-based measurement and monitoring systems
  • Quick and easy PROFIBUS connection for applications such as SCADA or MES

Quick and Easy Installation

  • Simple connection via USB cable
  • Powered by USB, no external power supply required
  • Highly integrated hardware encased in a PROFIBUS connector supporting direct attachment to the PROFIBUS segment, thus avoiding interferences caused by reflections
  • Same driver setup and API as for all other Softing PROFIBUS interfaces
  • Support of various Microsoft operating systems, including Windows 10

Efficient Integration

  • Free PROFIdtm PROFIBUS Communication DTM supporting parameterization of PROFIBUS devices by FDT tools
  • Commented sample programs for easy use of the PROFIBUS application programming interface (API) in customer applications
  • Quick and easy integration of OPC Client applications via optional PROFIBUS OPC Server
  • Connectivity with Emerson’s AMS for access to HART devices via a PROFIBUS network using Softing’s free TACC software
PROFIBUS Protocol • PROFIBUS DP-V0 Master
• PROFIBUS DP-V1 Master: acyclic C2 Services
Fieldbus Connection 9-pin D-Sub connector
Transfer Rates 9.6; 19.2; 45.45; 93.75; 187.5; 500; 1500; 3000; 6000; 12000 kbps
PC Interface USB 2.0, High Speed (480 Mbps)
Status LEDs Multicolored LED indicators for PROFIBUS and USB
Operating Temperature 0 ºC .. +60 ºC
Storage Temperature -20 ºC .. +70 ºC
Relative Humidity < 90%, non-condensing
Housing Metalized plastic
Dimensions 64 mm x 40 mm x 17 mm
Power Supply Supply voltage: 5 V via USB
Current consumption: typically 350 mA (USB)
Drivers available for Windows XP, Windows 7, Windows 8, Windows 10
Conformity FCC VCCI

DUL-NN-012410

PBpro USB

Scope of Delivery

Hardware PBpro USB hardware, USB cable
Software Drivers, Sample programs on CD-ROM
Documentation On CD-ROM

Additional Products and Services

OPC-PB PROFIBUS OPC Server for DP-V0/DP-V1

PROFIBUS Training course available on demand

People having seen this page can be interested in :

PB-PRO1-PCIE

Universal PCI Express Boards for Use as Master or Slave

Single and dual channel interface boards in PCI Express format ( PB-PRO1-PCIE) for integrating PCs into PROFIBUS architectures as machine controllers, supervisory control applications, field devices or operator panels.

Support of PROFIBUS Master or Slave Functionality

The protocol required for the specific use case is user selectable and executed on the PB-PRO1-PCIE board. As a DP slave, the board integrates the PC into overlying control architectures. Configured as a DP master, the board turns the PC itself into the controller. As a DP Master Class 2, it provides the basis for parameterization and asset management tasks. In addition, integration into FMS systems or proprietary applications is just as easy and unproblematic as direct access at the lowest protocol level (FDL). This makes the PBpro PCI Express a universal interface solution and allows manufacturers to optimize the overhead costs and the inventory for their PROFIBUS options.

Rapid Integration With the Right Software Interface

The included PROFIBUS driver software is complemented with many sample programs that demonstrate how to use the PROFIBUS API. Commented sample programs show how this is done. A matching Softing OPC Server, which is available as an optional standard interface, quickly and easily connects any application that has an integrated OPC client. Typical applications include visualization, SCADA or MES systems. FDT compliant parameterization tools use the PROFIdtm Communication DTM from Softing as a link to the PB-PRO1-PCIE board. Used with the free STEP7 driver, the board can also provide a PG/PC adapter for programming Siemens controllers.

Application in a Wide Variety of Target Systems

In addition to standard Windows environments, the PBpro PCI Express board also supports Windows CE.NET as a real-time environment. On request, Softing’s team of engineers can customize the board according to customer specifications.

Master/Slave, Single Channel 1)  Slave, Single Channel 1) Master/Slave, Dual Channel
PROFIBUS Protocol
DP-V0 Master
DP-V1 Master: Acyclic C2 Services
FMS
FDL
DP-V0 Slave
Fieldbus Connection 9-Pin D-Sub Female, RS485, Galvanically Isolated
Transfer Rates 9.6; 19.2; 45.45; 93.75; 187.5; 500; 1500; 3000; 6000; 12000 Kbit/s
PC Interface PCI Express x1 According to PCIe r1.0a and CEM 1.1, 512 KB Shared RAM per Channel
Operating Temperature 0 oC .. +55 oC
Storage Temperature -20 oC .. +70 oC
Relative Humidity < 90%, Non-Condensing
Dimensions [mm] 168 x 69  168 x 69 168 x 103
Power Supply
Supply Voltage 3.3V / 12V (± 5%) DC
Current Consumption [mA] typ. 500 / 90 typ. 500 / 90 typ. 640 / 170
Drivers available for Windows 2000, Windows XP, Windows Vista, Windows 7, Windows 8, Windows 10
Conformity
PB-PRO 1-PCIE (PB-PRO 1-PCIE/LP1)) Master/Slave, Single Channel 1)
PB-PRO 1S-PCI E(PB-PRO 1S-PCIE/LP1)) Slave, Cingle Channel 1)
PB-PRO 2-PCIE Master/Slave, Dual Channel

Scope of Delivery

PC interface Board, CD with Drivers, Documentation and Sample Programs

Additional Products and Services

OPC-PB PROFIBUS OPC Server for DP-V0 / DP-V1
DCF-DY-4100 OPC Server for S7 / S5
TRA-PB-TECH PROFIBUS Technology Training

1) Also Available with Low Profile Slot Bracket

PB-PRO1-PCI

PB-PRO1-PCI

Universal PCI Boards for Use as Master or Slave. Single and dual channel interface boards in universal PCI format for integrating PCs into PROFIBUS architectures as machine controllers, supervisory control applications, field devices or operator panels.

csm_PBproPCI_D_EN_160801_201_a68cf76cc9

Always the Fitting PROFIBUS Protocol

  • PROFIBUS Master and Slave functionality
  • Support of PROFIBUS DP, PROFIBUS FMS and PROFIBUS FDL protocols
  • Universal interface solution for integration in industrial and embedded PCs

Rapid Integration Using API or OPC Server

  • Direct access to all protocols via PROFIBUS API
  • Sample programs including comments
  • Integration in various plant asset management tools
  • Optional access by OPC Clients using Softing‘s OPC Server

Large Choice of Drivers

  • Use in Windows and Linux operating systems
  • PROFIBUS CommDTM for FDT applications included in scope of delivery
Master/Slave, Single Channel 1) Slave, Single Channel 1) Master/Slave, Dual Channel
PROFIBUS Protocol  
DP-V0 Master
DP-V1 Master: Acyclic C2 Services
DP-V2 Master 2)
FMS
FDL
DP-V0 Slave
Fieldbus Connection 9-Pin D-Sub Female, RS485, Galvanically Isolated
Transfer Rates 9.6; 19.2; 45.45; 93.75; 187.5; 500; 1500; 3000; 6000; 12000 Kbit/s
PC Interface PCI V2.2, 128 KB Shared RAM per Channel
Operating Temperature 0oC..+55oC
Storage Temperature -20oC..+70oC
Relative Humidity < 90%, Non-Condensing
Dimensions [mm] 168×64 168×64 168×107
Power Supply
Supply Voltage 5V/3.3V(±5%)DC
Current Consumption [mA] Typ. 500 / 200 Typ. 500 / 200 Typ. 700 / 300
Drivers available for Windows 2000, Windows XP, Windows Vista, Windows 7, Windows 8, Windows 10
Linux
Conformity

1) Also Available with Low Profile Slot Bracket
2) DP-V2 Available for Custom Integration. Please contact Softing to discuss your specific requirements.

PB-PRO 1-PCI (PB-PRO 1-PCI/LP1)) Master/Slave, Single Channel 1)
PB-PRO 1S-PCI (PB-PRO 1S-PCI/LP1)) Slave, Single Channel 1)
PB-PRO 2-PCI Master/Slave, Dual Channel

Scope of Delivery

PC interface Board, CD with Drivers, Documentation and Sample Programs

Additional Products and Services

OPC-PB3) PROFIBUS OPC Server for DP-V0 / DP-V1
DCF-DY-41003) OPC Server for S7 / S5
TRA-PB-TECH PROFIBUS Technology Training

1) Also Available with Low Profile Slot Bracket
3) Requires PROFIBUS Master Interface Board

Training available.. please contact us