mbGate PB

MODBUS TCP SERVER to PROFIBUS PA/DP Master Gateway

imple connection of PROFIBUS Slave Devices to Modbus Control Systems via Internal I/O Mapping

With mbGate PB it is possible to integrate up to 2 PROFIBUS PA segments and 1 PROFIBUS DP segment into Modbus TCP control systems. It acts as Modbus TCP Server and PROFIBUS Master. With our gateway the engineering costs can be reduced since it re-uses existing power conditioners in technology upgrade projects. It enables configuration, parameterization and plant asset management using standard industry tools.

Similar solutions:
mbGate PA: Modbus TCP to PROFIBUS PA Gateway – Integrate PROFIBUS PA segments into Modbus Control system
mbGate DP: Modbus TCP to PROFIBUS DP Gateway – Integrate PROFIBUS DP segments into Modbus Control system

Key Component for Transition to State-of-the-Art Technology

  • Simple replacement of installed PROFIBUS DP/PA segment couplers
  • Re-use of existing PROFIBUS segments without requiring modification

Direct Connectivity to PROFIBUS Segments

  • Single access point to PROFIBUS DP and PROFIBUS PA segments from Modbus TCP networks
  • Acting as Modbus TCP Server and PROFIBUS PA and PROFIBUS DP Master
  • Support of one PROFIBUS DP segment and up to two PROFIBUS PA segments

Configuration, Parameterization and Plant Asset Management Using Standard Industry Tools

  • Supports major Modbus engineering tools such as Schneider Unity Pro or Siemens TIA Portal
  • Included CommDTM allowing use in FDT/DTM frame applications
  • EDD-based device parametrization using Siemens Simatic PDM

MODBUS/TCP Redundancy

  • Supports the use of two redundant PLCs and two redundant gateways
  • Easily enabled via licensing
  • Full control of redundant operation mode via engineering and PLC
Scope of Delivery
Hardware mbGate PB Gateway
Documentation On Website
Order Numbers
GCA-EN-024808 mbGate PB, Modbus TCP to PROFIBUS Gateway. Supports 2 PA segments (up to 32 PA devices, MBP physical layer) and 1 PROFIBUS DP segment (RS485).
Additional Products and Services
LRA-EN-024851 gatePlus HighAvailability, License for activating redundancy features in mbGate PB
LRL-DY-134501 dataFEED OPC Suite, Version 4.01 and higher, including all supported PLC protocols, support for OPC UA, access for any number of dataFEED OPC Tunnel Clients, for simultaneous access to a total of up to 100 OPC UA Servers, OPC Servers and OPC Tunnel Servers, and many more Functionalities such as Database and File Access, Data Exchange, Optimizer, Concentrator and Bridge
GCA-EL-024802 mbGate PA, Modbus TCP to PROFIBUS PA Gateway. Supports up to 2 PA segments (up to 32 PA devices).
GCA-EL-024804 mbGate PA, Modbus TCP to PROFIBUS PA Gateway. Supports up to 4 PA segments (up to 64 PA devices).
GCA-EN-024806 mbGate DP, Modbus TCP to PROFIBUS DP Gateway. Supports 1 PROFIBUS DP segment (RS485).
Fieldbus Infrastructure
Installation solutions When using the high-power trunk topology or FISCO, we offer in cooperation with R.Stahl, fieldbus infrastructure components with PROFIBUS PA and FOUNDATION fieldbus H1 – this ranges from power supply, physical layer diagnostics and field device couplers to termination resistors.

datacheck analyzer software product bundle for mobile industrial ethernet diagnostics

Analyzer IE & Analyzer PRO

Software for Mobile Diagnostics and Acceptance Testing of Industrial Networks

Analyzer IE / PRO is a comprehensive software solution for acceptance testing and efficient troubleshooting of Ethernet-based industrial communication. In a PROFINET environment, the mobile diagnostic tool generates standardized acceptance reports in accordance with the recommendations of PROFIBUS & PROFINET International (PI), making it an easy-to-use product that is tailored to the needs of plant suppliers, maintenance personnel as well as service providers.

This product belongs to our PROFINET Diagnostics family. In order to view our expertise and the complete list of products please Download the PROFINET Diagnostics Brochure.

Comprehensive Functionality

  • Diagnostics list, error statistics, network statistics
  • Enhanced flexibility by supporting online as well as offline mode
  • Generation, analysis and handling of diagnostic data such as graphical topology, inventory list and reference measurements, also for standard Ethernet components (eg PCs, camera systems)

Automated Generation of Acceptance Test Documents

  • Time saving by automatically created test reports
  • Flexible definition of acceptance criteria
  • Transparent reporting by following PI guidelines

Tool Addressing Complete Plant Lifecycle

  • Data on network configuration, network communication and diagnostic messages
  • Error identification for effective troubleshooting (e.g. based on inventory list of network devices)
  • Chance to support exchange of general project information between end users, EPC contractors, system integrators and maintenance service providers
  • Seamless integration with Softing diagnostics per-manent monitoring solutions TH SCOPE and TH LINK
Technical Data
Functionality
  • Analysis of device logs
  • Live list, statistics, inventory
  • Topology and trend analysis
  • GSDML file support, plaintext messages in diagnostic list
  • Acceptance measurements and acceptance reports
  • Reference comparison
  • Configurable time intervals for automated export of inventory and topology data
  • Data export via Excel
  • Configurable Blacklist feature for robust operation
  • Optional (Analyzer PRO): Telegram analysis: jitter, refresh interval, load ratio
Supported Protocols PROFINET, EtherNet/IP, Modbus TCP
Interfaces
  • SNMP Agent
  • OPC UA Server
System Requirements Adobe Reader 8 or higher for reading the documentation and for printing the topology
Supported Operating Systems Windows 7, Windows 8.1, Windows 10
Windows Server 2012, Windows Server 2012 R2, Windows Server 2016
Network Access Data collection through TH LINK PC (PROFINET, EtherNet/IP, Modbus TCP)
Demo Version Full TH SCOPE functionality can be used for free for 30 days after installation
Licensing Software or hardware key
Scope of Delivery
Software Analyzer IE
License Software key (bound to PC) or hardware key
Hardware profiTap: Network tap for telegram analysis operation, optional (Analyzer PRO)
Documentation Installation manual, user manual, release note
Order Numbers
LRA-JY-003041 Analyzer IE (software key)
LRL-JY-003042 Analyzer IE (hardware key)
KPL-JY-003043 Analyzer PRO
Additional Products and Services
GEA-JN-003006 TH LINK PROFIBUS
GDA-JA-003034 TH LINK PROFINET
GDA-JY-003037 TH LINK Industrial Ethernet
LRA-JY-003028 TH LINK PC Industrial Ethernet
TRA-PB-TECH Training “PROFIBUS Technology”
TRA-PB-TS Training “PROFIBUS Troubleshooting with exam to Certified PROFIBUS Installer”
TRA-PN-CERTINST Training “PROFINET Acceptance and Commissioning”
TRA-PN-CERTENG Training “PROFINET Technology graduated as Certified PROFINET Engineer”
TRA-PN-TOOLS On-site training: PROFINET tools

Please contact us

People interested in this product, may be interested in :

 

Echochange

echochange

Ethernet Gateway for the Connection of Different Controllers

The echochange protocol converter supports Ethernet TCP/IP protocols of such leading manufacturers as Siemens, Schneider Electric and Rockwell Automation. This simple protocol conversion makes communication between automation systems of different manufacturers quick and easy.

 

Protocol Conversion for Data Exchange between Multi-Vendor Automation Systems

  • Integration of robust control technology without having to adjust control software
  • Combination of separate networks with different media via configured connections
  • Connection of physically separate networks with different media or heterogeneous networks with identical medium
  • Connection of data from different control systems via allocation tables
  • Bi-directional conversion and writing of PLC data via configured connections
  • Analysis of device functionality and extensive Ethernet diagnostics

Support of Multiple Industrial Standard Protocols

  • Support of TCP, UDP, IP, ISO (H1), ISO on TCP (RFC1006), PLC Header, EtherNet/IP Ethernet protocols
  • Linking of computers with TCP/IP to ISO (H1) networks
  • Remote maintenance of ISO (H1) networked controllers via TCP/IP
  • Routing support for controllers

Investment Protection and IT Maintenance Cost Reduction

  • Standard component for extending functionality without modifying existing systems
  • Very easy configuration through straight-forward project import without requiring control modifications and programming skills
  • Remote configuration and diagnosis via remote maintenance if required
  • No need for additional PC with software updates and additional administration
  • Working for years once configured – untouched, without updates, and with zero maintenance costs
  • Supporting plug-and-go replacement if required based on configuration data stored on SD card
Ethernet Addressable Controllers Siemens S7 and S5, Rockwell Automation ControlLogix, CompactLogix, PLC-5 and SLC-500, Modbus TCP controllers (e.g. Schneider Electric, Phoenix, Contact Wago, Beckhoff), Mitsubishi (Melsec-Q), etc.
Ethernet Protocols TCP/IP, RFC1006 (ISO on TCP), ISO (H1), EtherNet/IP, AB Ethernet, S5, S7, CLX, SLC, Send/Receive (raw data / socket), TCP/IP with PLC header, Modbus TCP, Melsec-Q, DLMS, DCU
Protocol Conversion
  • RFC1006: to ISO(H1), CLX/SLC, AB Ethernet, Melsec-Q, Modbus TCP
  • ISO (H1): to RFC1006, ISO(H1), CLX/SLC, AB Ethernet, Melsec-Q, Modbus TCP
  • Modbus TCP: to RFC1006, CLX/SLC, AB Ethernet, Melsec-Q
Ethernet Interfaces 2xTP (RJ45), 10/100MBit/s
Power Supply 24VDC, ca. 0,3A
Ambient Conditions Operating Temperature: 0 to 55 °C,  Storage Temperature: -20 to 70 °C
Dimensions (HxWxL) 131mm x47mm x 111mm
Weight ca. 0,4kg
Mounting 35mm DIN Rail
Protection Class IP20
Certifications CE, FCC, VCCI
GPL-YY-142101 echochange, Maximum 10 Connections;
Connectors: 2xEthernet
LRA-YY-142001 Upgrade echochange: Maximum 30 Connections

Additional Products and Services

700-5596-04 AC Adapter, 24VDC, Euro, UK, or USA
120-1010-05 Telephone support: application consulting, fees charged on a time and materials basis
110-1000-01 Training “Industrial Ethernet: Troubleshooting in Automation Plants“, 3 days

Scope of Delivery

Hardware Protocol converter echochange, SD Card 2 GB, connector for power supply*
Software Configuration software NetCon on CD-ROM
Documentation Quick Start leaflet, integrated help , product manual on CD-ROM

* A plug-in powerpack is not included. If necessary, please order this separately.

For training courses, please ask

Connector Power Pack 24 V DC

Country-specific connector power packs are available. Note: A connector power pack is not included in the delivery of the echochange. If necessary please order it separately.

Technical Details

100 – 240 V AC, 47 – 63 Hz, sec. 24 V, 1,25A

THScope

Management and Diagnostics for Industrial Networks

TH SCOPE is a software product for industrial network management and network diagnostics. Geared to plant operators and maintenance personnel, TH SCOPE is an all-in-one, easy-to-use solution for permanent monitoring and predictive maintenance, for acceptance testing and for troubleshooting. Combined with TH LINK components, the product supports PROFIBUS, PROFINET, EtherNet/IP and Modbus TCP protocols.
The PROFINET Commissioning Report functionality is now available in new THSCOPE Release. Download the new THSCOPE under ‘Downloads’ section.

Comprehensive Presentation and Evaluation of Diagnostic Data

  • Provision of data on network communication, network configuration and diagnostic messages
  • Preparation of standardized exports (e.g. for acceptance testing)
  • Support of PROFIBUS, PROFINET, EtherNet/IP and Modbus TCP in combination with TH LINK components
  • Data acquisition also from standard Ethernet devices (e.g. PCs or camera systems)

Versatile solution for a wide range of diagnostic applications

  • Permanent monitoring and alerting
  • Commissioning and acceptance
  • Network documentation
  • Network and Plant Asset Management
  • Fault localization and identification

Flexible System and Process Integration

  • Web-based access, local or remote
  • Integration of inventory data into monitoring tools and process control systems via OPC UA
  • Export of diagnostic data for further processing in other applications (e.g. MS Excel)
  • Easy data exchange with Softing‘s Analyzer IE software (e.g. export of reference measurement)
  • Intuitive handling and operation
Technical Data
Functionality
  • Network overview with network and device status plus diagnostic messages with troubleshooting recommendations
  • Analysis of device logs
  • Live list, statistics, inventory
  • GSDML file support, plaintext messages in diagnostic list
  • Topology and trend analysis
  • Automatic e-mail notification in case of fault
  • Reference comparison
  • Acceptance measurements and acceptance reports
  • Configurable time intervals for automated export of inventory and topology data
  • Data export via Excel
  • Output of inventory data via OPC UA
Supported Protocols PROFINET, PROFIBUS, EtherNet/IP, Modbus TCP
Interfaces
  • SNMP Agent
  • OPC UA-Server
  • OPC Classic DA-Server
System Requirements
  • Web browser with Adobe Flash Player 14 or higher
  • Adobe Reader 8 or higher for reading the documentation and for printing the topology
Supported Operating Systems Windows 7, Windows 8.1, Windows 10
Windows Server 2012, Windows Server 2012 R2, Windows Server 2016
Network Access Data collection through TH LINK (PROFIBUS, PROFINET, EtherNet/IP, Modbus TCP und Industrial Ethernet)
Demoversion Full TH SCOPE functionality can be used for free for 30 days after installation
Licensing Via software or hardware key
Scope of Delivery
Software TH SCOPE (by download from Softing‘s website industrial.softing.com)
License Software or hardware key
Documentation Installation Manual, User Manual, Release Note
Order Numbers
LRA-JY-003024 TH SCOPE (software key)
LRL-JY-003025 TH SCOPE (hardware key)
Additional Products and Services
GEA-JN-003006 TH LINK PROFIBUS
GDA-JA-003034 TH LINK PROFINET
GDA-JY-003037 TH LINK Industrial Ethernet
LRA-JY-003028 TH LINK PC Industrial Ethernet

TH SCOPE:
If your network is protected by a second firewall in addition to the Windows firewall, make sure that the following settings are made to allow TH SCOPE services to communicate properly.

  • Enabling of HTTP port 80 – inbound and outbound
  • Enabling of SNMP port 161 inbound or port 2367 (if port 161 is used by another SNMP agent).
  • Enabling of IP 224.0.5.128 port 2364 UDP outbound
  • Enabling of UDP ports 2365 outbound and 2366 inbound

 

The following ports are used by TH SCOPE for internal communication only:

  • Port 22
  • Port 80
  • Port 1100
  • Ports 1123 – 1151
  • Port 1500
  • Port 1501
  • Ports 2363 – 2366
  • Ports 49152 – 49171

I am text block. Click edit button to change this text. Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.

People interested in this product, can be interested in :

THLink Industrial Ethernet

Industrial Ethernet Network Diagnostics Independent from Controller and Control Room

The TH LINK Industrial Ethernet diagnostics tool makes use of a controller-independent access to monitor PROFINET, EtherNet/IP and Modbus TCP networks. The diagnostic data is collected in networks comprising up to 254 nodes, and made available to users through the TH SCOPE software application. TH LINK Industrial Ethernet is easy to use and can be integrated without interfering with the operation of existing installations.

csm_THLink_IE_D_EN_170101_311_fbdb7e6c27

Independent Access to PROFINET, EtherNet/IP and Modbus TCP Networks

  • Controller-independent
  • Independent of configuration tools
  • Only one tool needed to monitor multiple IP subnetworks (up to 254 nodes, one or more controllers

Designed for Installation without Interference with Plant Operation

  • Connection to free port in industrial network, also possible during operation of the plant
  • No need to install TAPs or use mirror ports
  • Highest security (separate accesses for control room level and plant level, no routing)
  • Easy integration into existing plants thanks to compact design

Powerful Data Collection Capabilities Optimized for Ethernet-Based Industrial Communication

  • Support of the PROFINET, EtherNet/IP and Modbus TCP protocols
  • Collection also from standard Ethernet devices (e.g. PCs or camera systems)
  • PROFINET supervisor in PROFINET networks
  • Network load limit according to PROFINET guidelines

Optimized for Use by Maintenance Engineers

  • Suitable for network acceptance testing, continuous monitoring and troubleshooting
  • Easy and intuitive handling and operation
  • Fault identification with intelligent troubleshooting assistance
  • Seamless integration with TH SCOPE diagnostics software
Functionality
  • Network detection and data collection
  • Alarm notification in case of fault
  • Basic monitoring, configuration
  • Integrated web server
Input Voltage 24 VDC (18 VDC … 32 VDC)
Current consumption max. 180 mA
Current consumption relay contact max. 100 mA
Operating Temperature -40 °C … +75 °C
Relative Air Humidity 5 … 95 % (no condensation)
Ethernet Ports RJ-45 (10Base-T/100Base-TX)
Supported SD Cards See Release Notes
Mounting 35 mm DIN rail
Dimensions (HxWxD) 22.5 x 99 x 114.5 mm
Weight 120 g
Certifications CE
GDA-JY-003037 TH LINK Industrial Ethernet

Scope of Delivery

Hardware TH LINK Industrial Ethernet
Documentation Installation Manual, Release Note (by download)

Additional Products and Services

ATV-LRA-JY-003024 TH SCOPE (software key)
ATV-LRL-JY-003025 TH SCOPE (hardware key)
ATV-LRA-JY-003028 TH LINK PC Industrial Ethernet (software key)
ATV-LRL-JY-003029 TH LINK PC Industrial Ethernet (hardware key)
ATV-TRA-PN-TECH Training “PROFINET Technology”
ATV-TRA-PN-CERTENG Training “PROFINET Commissioning and Troubleshooting”

dataFEED OPC Suite – Modbus TCP

dataFEED OPC Modbus TCP

Quick and convenient access to PLC data via OPC and OPC UA

The dataFEED OPC Server Modbus is a component of the dataFEED OPC Suite and combines the functionality for quick and convenient access to process and diagnostic data within Modbus compatible controllers.

csm_dataFEEDOpcServerMb_D_EN_160801_210_846fa69df4

Easy Access to Modbus Controllers

  • Read and write access to data in Modbus controllers
  • Quick and easy integration into OPC Client applications, such as SCADA or ERP systems
  • No changes to control program required

Graphical User Interface with Configuration Wizards

  • Easy-to-use graphical configuration interface
  • Intelligent wizards for configuration setup in just 3 clicks
  • Configuration of OPC Namespace e.g. by importing symbolic names from CoDeSys (Wago) project
  • CSV import of existing configurations from software applications like SCADA or process control systems

Support of OPC Unified Architecture (UA)

  • Optional expansion through dataFEED OPC Organizer UA
  • Integration of non-OPC UA-ready components into OPC UA applications
  • Easy integration of legacy and new controllers into “Industrie 4.0” *solutions
  • Cost savings through continued use of OPC Classic components
  • Support of all security mechanisms defined by OPC UA standard

*Industrie 4.0 is a German government-driven initiative for implementing an industrial “Internet of Things”

Supported dataFEED OPC Suite Features OPC Server, Filter, Optimizer, Concentrator, Bridge, optional OPC UA Server
Supported Controllers Modbus TCP-compatible controllers (Wago, Beckhoff, Phoenix, Schneider, etc.)
Accessible Controller Data Inputs, outputs, data blocks, markers, timers, counters
Supported Modbus Data Types BIT, BYTE, WORD, DWORD, REAL, STRING, DATE, TIME, and arrays of these data types
Supported OPC Specifications OPC Classic Data Access V1.0a, V2.05, V3.0, OPC Classic XML-DA V1.01, OPC Unified Architecture V1.02 (optional)
Supported OPC Data Types VARIANT Data Types I1, UI1, I2, UI2, I4, UI4, R4, DATE, BSTR, BOOL and arrays (VT_Array) of these data types
OPC Certification Test using OPC Foundation‘s Compliance Test Tool
Operation Mode Application (OutProc Server), Windows Service
Logging, Diagnostics Logging of OPC Calls and Notifications, OPC Data, OPC Tunnel frames, text file access (optional), database access (optional), configurable via integrated web server diagnostic interface
Supported Operating Systems Windows XP, Windows 7, Windows 8, Windows 8.1, Windows Embedded 8.1 Industry, Windows 10Windows Server 2003, Windows Server 2008, Windows Server 2008 R2, Windows Server 2012,Windows Server 2012 R2
Licensing Runtime license per computer
Demo Version Full dataFEED OPC Suite, time limited to 72 hours
LRL-DY-132401 dataFEED OPC Server Modbus component of dataFEED OPC Suite, Version 4.01 and higher, for communication with Modbus-compatible PLCs, includes dataFEED OPC Organizer Classic functionality
LRL-DY-134201 dataFEED OPC Organizer UA component of dataFEED OPC Suite, Version 4.01 and higher, suitable for access by any number of OPC UA Clients and for access to 1 OPC UA Server, includes dataFEED OPC Organizer Classic functionality
HUA-DD-130001 USB Hardware Key for dataFEED OPC Suite, Version V4.01 and higher, replacing the standard Software Key

Scope of Delivery

dataFEED OPC Server Modbus Software on CD-ROM
Documentation Manual in PDF format and Online Help in English and German

Additional Products and Services

LRL-DY-134501 dataFEED OPC Suite, Version 4.01 and higher
LRL-DY-134001 dataFEED OPC Tunnel component of dataFEED OPC Suite, Version 4.01 and higher
LRL-DY-132301 dataFEED OPC Server Rockwell component of dataFEED OPC Suite, Version 4.01 and higher
LRL-DY-132101 dataFEED OPC Server Siemens component of dataFEED OPC Suite, Version 4.01 and higher
LRL-DY-132601 dataFEED OPC Server Mitsubishi component of dataFEED OPC Suite, Version 4.01 and higher
LRL-DY-132901 dataFEED OPC Server B&R component of dataFEED OPC Suite, Version 4.01 and higher
LRL-DY-134301 dataFEED OPC Data Handler component of dataFEED OPC Suite, Version 4.01 and higher
LRL-DY-134401 dataFEED OPC Server Extension License 50 for dataFEED OPC Suite, Version V4.01 and higher
LRL-DY-134601 dataFEED OPC Server Extension License 100 for dataFEED OPC Suite, Version V4.01 and higher

People interested in this product may be also interested in:

dataFEED uaGate MB

dataFEED uaGate Modbus TCP

Gateway for OPC UA and MQTT Communication Access to Modbus TCP PLCs

  • Integration of modern OPC UA communication functionality
  • Symbol import of controller data using web interface
  • Usage of high security standards for protecting transferred data
csm_uaGateMB_D_EN_171101_100_d5f17590dc (1)

Access to Data in Modbus PLCs from OPC UA Applications

  • Access to Modbus controllers, e.g. from Schneider Electric, Wago, Beckhoff, Phoenix Contact, etc.
  • Integration of higher-level management systems like ERP, MES or SCADA using integrated OPC UA Server providing open, platform-independent and market-proven communication
  • Easy local and global access to field data and routing through firewalls
  • Especially dedicated to retrofit upgrades, thus protecting former investments
  • No need for software updates, operating system patches and PC updates resulting in years of failure-free operation
  • Minimal PLC programming for register setup required
  • No dedicated PC required

PLC Project Data Available for Further Processing

  • Symbol import from user-edited text file
  • Easy setup of OPC UA Server requiring only a few steps for accessing data in Modbus PLCs
  • Web-based interface for gateway configuration

Industry-proven Security

  • Physically separated interfaces and separate configuration rights for OT and IT networks preventing intrusions
  • Supporting security standards as SSL/TLS and X.509 certificates
  • OPC UA compliant data encryption and user authentification
  • Security supported for MQTT communication with private and public clouds
Hardware Processor Altera Cyclone V SoC with Dual-core ARM Cortex-A9
Connectors 2 x IEEE 802.3 100BASE-TX/10BASE-T (independent interfaces)
Status LEDs PWR (power supply), RUN (running), ERR (error), SYS (configuration)
Dimensions (H x W x D) 100 mm x 22.5 mm x 105 mm
Power Supply 18 VDC … 32 VDC, SELV/PELV supply mandatory Typically 200 mA, maximum 1 A at switch-on
Operating Temperature, Horizontal DIN Rail Installation -40 °C .. 50 °C (0 mm minimum distance)
-40 °C .. 55 °C (22.5 mm minimum distance)
Operating Temperature, Vertical DIN Rail Installation -40 °C .. 35 °C (0 mm minimum distance)
-40 °C .. 40 °C (22.5 mm minimum distance)
Storage Temperature -40 °C .. 85 °C
Relative Humidity 10 % … 90 %, non-condensing
Weight About 0.2 kg
Mounting DIN Rail (35 mm)
Housing Phoenix Contact ME MAX
Protection Class IP20
Software Protocols Modbus TCP, OPC UA (Server, 20,000 items in total), MQTT (Publisher, up to 1,000 topics)
Supported Controllers Modbus TCP controllers, e.g. from Schneider Electric, Wago, Beckhoff, Phoenix Contact, etc.
Conformity Emission EC Directive 2004/108/EC “Electromagnetic Compatibility”, EN 55011, Group 1, Class A
EC Directive 2004/108/EC “Electromagnetic Compatibility”, EN 55022, Class A
EC Directive 2004/108/EC “Electromagnetic Compatibility”, EN 61000, Part 6-4
FCC CFR45, Part 15 Section 15.107 and 15.109 (Class A),
VCCI Class A Information Technology Equipment 2002
Immunity EC Directive 2004/108/EC “Electromagnetic Compatibility”, EN 61000, Part 6-2
ATV-GAA-YE-145133 uaGate MB

Scope of Delivery

Hardware uaGate MB
Software Tool for configuration over integrated web interface
Documentation Quick Startup Guide (printed documentation)

People interested in this product may be interested in :

Echocollect e

The Echocollect gateway

The Ecocollect is a gateway for the Integration of Process Data with Higher-level Systems and IoT Solutions

SOFTING echocollect

echocollect e is an industrial multi-protocol gateway providing a modern process data management solution. It offers bidirectional real-time connectivity between PLCs and databases, and direct OPC UA and OPC Classic connectivity. Its functionality includes both local data logging and direct integration of data into IoT cloud applications via MQTT.

New with the echocollect ???

Echocollect Presentation ( PDF )

Integration of Existing Systems in New Quality Assurance Systems

  • Independent real-time collection of manufacturing, process or quality data directly from programmable logic controllers (PLC) and delivery to higher-level management systems, such as ERP or MES system
  • Recipe manager functionality for writing data blocks to PLCs
  • Direct connectivity via SQL database protocols, platform independent OPC UA technology or MQTT Publisher functionality
  • Support of more than 50 PLC types addressable via Ethernet

Excellent Data and Network Security

  • Buffering of arriving data and addition of time stamps in case of broken connections, automatic forwarding once connection has been reestablished
  • Option for parallel data logging on SD card for traceability reasons
  • Physical network separation between production systems and commercial IT networks
  • State-of-the-art OPC UA security: Optional encryption of transmitted data and authentication via certificates

Lowered IT Maintenance Costs and Investment Protection

  • echocollect as standard component, addition of extra functionality without modifying existing systems
  • No need for additional PC requiring software updates and administration
  • Working for years once configured – untouched, without updates and with zero maintenance costs
  • Plug-and-go replacement, if necessary, using configuration stored on SD card
  • Very easy configuration by straightforward project import without requiring PLC modifications and programming skills

Easy Live Data Visualization

  • Native web technology for easy and cost-efficient visualization of process, manufacturing and quality data using standard web browser without any plug-ins
  • No need for OPC Server or complex SCADA system
  • Scalable, resolution-independent vector graphics for consistent display of data on wide variety of network enabled devices like desktop PCs, laptops, smart phones, tablet PCs or industrial control panels
Ethernet Addressable Controllers Siemens SIMATIC S7 and S5, controllers with Modbus TCP (Wago, Beckhoff, Phoenix Contact, Schneider Electric, etc.), Mitsubishi (Melsec-Q), etc.
Ethernet Protocols TCP/IP, RFC1006 (ISO on TCP), ISO (H1), S5, S7, TCP/IP with PLC header, Modbus TCP, Melsec-Q, raw data
Ethernet Interfaces 2 x independent interfaces TP (RJ45), 10/100 MBit/s
Embedded OPC UA Server Symbolic Mapping; Browsing, Read, Write, Subscribe; Self-Discovery Service; possible reconfiguration without device restart; possible multiple Client connections, optional read-only PLC connection; OPC UA Security with password or certificates
Embedded MQTT Publisher Establishment of MQTT Broker connection, optional user authentication and data encryption, easy topic generation from existing symbols, maximum of 1,000 topics, adjustable publishing interval
Supported Databases MySQL, Oracle, DB2, MS-SQL
Other Protocols Telnet, SMTP (email notification), OPCpipe (OPC Tunnel)
Supported Engineering Tools for Symbol Import SIMATIC STEP 7, TIA Portal
Limitation Maximum of 5 PLC connections, 10,000 items in total
Data mapping PLC – database must be structured in 400 tables and 200 items per table
Visualization atvise webMI visualization, functional level ‘Advanced’ (fully event-driven data exchange) Limited to up to 50 visualized items per echocollect (optional upgrade possible), maximum of 5 simultaneously accessing browsers
Configuration Software Softing NetCon for device configuration, atvise builder for SCADA project editing, dataFEED Exporter for symbol import
Power Supply 24 VDC, ca. 0,3 A
Ambient Conditions Operating temperature: 0 °C … 55 °C, storage temperature: -20 °C … 70 °C
Dimensions (HxWxL) 131mm x 47mm x 111mm
Weight ca. 0,4 kg
Mounting 35 mm DIN Rail
Protection Class IP20
Certifications CE
GAL-YY-143101 echocollect e (connectors: 2 x Ethernet, 1 x TTY)
LRA-YY-143001 Upgrade echocollect: License for database access to Oracle, DB2 and MSSQL (default: MySQL only)
LRA-YY-143002 Upgrade echocollect: License enabling data logging on SD Card (default: no data logging)
LRA-YY-143004 Upgrade echocollect: License supporting unlimited number of visualization items (default: maximum of 50 visualization items)
LRA-YY-143005 Upgrade echocollect: License embedded OPC UA Server (default: no embedded OPC UA Server)
LRA-YY-143007 Upgrade echocollect: License MQTT Publisher functionality (default: no MQTT support)
LRA-YY-143115 Upgrade echocollect: License enabling maximum of 15 PLC connections (default: maximum of 5 PLC connections)

Additional Products and Services

700-5596-04 AC Adapter, 24 VDC, Euro, UK, or USA
LRL-DY-131701 OPCpipe client
MEA-YY-144002 CD atvise elements, 4,000 high-quality bitmaps and vector graphics in SVG format
GPL-CS-191000 echolink sS7-compact
110-1000-01 Industrial Ethernet – Troubleshooting in Automation, 3 days

Scope of Delivery

Hardware Multi-protocol gateway echocollect e, SD card, connector for power supply*
Software Net configuration software on CD-ROM, also downloadable from Softing website
Documentation Quick Start leaflet, context-based online help, CD-ROM with product handbook and configuration tutorials, also downloadable from Softing website

Connector Power Pack 24 V DC

Country-specific connector power packs are available. Note: A connector power pack is not included in the delivery of the echocollect. If necessary please order it separately.

Technical Details

100 – 240 V AC, 47 – 63 Hz, sec. 24 V, 1,25A

Order Number

Version EURO, UK, USA
700-5596-04

Which cloud platforms are supported?

We support with all Softing gateways (echocollect, uaGate, edgeGate) the Microsoft Azure Cloud, Amazon AWS Cloud, IBM Bluemix Cloud and other cloud providers, which are using MQTT for telemetry data.

What is the size of the Store & Forward queue on the echocollect?

The S&F queue for MQTT is unlimited (except the size of the sd-card). The echo buffers in the ram, and after it collects a bunch of messages, they were copied to the sd-card. To use the S&F feature, QoS 1 or QoS 2 must be used.

FG-200 HSE/FF Gateway

Modbus TCP/FF HSE to FOUNDATION Fieldbus H1 Gateway

Integration of up to 4 FF H1 segments into control systems via Modbus TCP or FOUNDATION Fieldbus HSE

FF Network Integration via Modbus Including Redundancy

With Softing’s FG-200FF, you can easily integrate up to four FOUNDATION™ Fieldbus (FF) H1 links into control systems supporting Modbus. The Softing FG-200FF provides redundancy and is suitable for use in ATEX zone. This device features fast access to process data, while making use of Fiedbus Foundation (FF) advantages like reduced cabling, central field device parameterization, comprehensive diagnostics, or intrinsically safe device segments. The Fieldbus foundation gateway (FG-200FF) is fully compatible with the R. STAHL bus-Carrier Series 9419 and Fieldbus Power Supply Series 9412 products for a very easy commissioning.

Easy Commissioning with the FG-200FF

  • Optional support of R. STAHL bus-Carrier Series 9419 and Fieldbus Power Supply 9412 products (cabling reduced to a minimum)
  • Modbus data import to web server reducing mapping efforts

Easy Asset Management thanks to the FG-200FF

  • Visitor mode avoiding interference with network behavior
  • Enabling asset management systems (e.g. Emerson’s AMS) and Field Device Tool (FDT) frame applications (e.g. SMART VISION, FieldMate, Field Device Manager, FieldCare, or PACTware)

The FG-200FF gateway makes easy the device redundancy

  • Redundancy link enabling device redundancy (D-3 according to FF-593)
  • Automatic mirroring of configuration data
  • Very fast redundancy switch-over between 2* FG-200FF Fieldbus foundation Gateway

All Necessary Tools Included

  • FF Configuration Tool for configuration of devices and cyclic communication
  • PACTware for device configuration and basic asset management tasks

FG-200FF vs FG-100FF

FG-110 FG-200
CPU PowerPC 805T 100 MHz Cortex A9 400 MHz
H1 Interface (MAU) Inductive coupling (no bus power required) Bus-powered (10 mA drawn from bus)
Ethernet Ports 1 2 (medium redundancy, same IP address)
Redundancy Communication Serial Link (115,2 kBit/s) and Ethernet Serial Link (1 MBit/s) only, no load on Ethernet
Cabling All connectors on front side Fieldbus: bottom
Ethernet: front
Power: top or power bus in DIN rail
Mechanical Compatibility STAHL bus carrier
Dimensions 131 mm x 47 mm x 111 mm 100 mm x 35 mm x 105 mm (- 46%)

Compatibility

Functionality Comments
Host Interface
Device Interface
Engineering Existing projects can be downloaded without any changes
Mechanical Dimensions Smaller in each dimension: Same cabinet can be used
Bus Power Supply 10 mA required per Link (same as for all devices and most host systems)
FISCO Power Supplies with separate host interface must provide 10 mA on host side
Cabling Different positions, different connectors: Cables have to be modified
Redundancy Management FG-100/FG-110 and FG-200 cannot cooperate as redundant pair: No replacement of FG-110 by FG-200 in run possible. Complete redundant pair of Linking Devices has to be replaced at same time.
Hardware Processor
Status LEDs (Gateway)

Status LEDs (Fieldbus)
Altera Cyclone V SoC with dual-core ARM Cortex-A9
PWR (power supply), RUN (operation), ERR (error), RDL (redundancy link)
FF H1 activity per link
Interfaces and Connectors Ethernet


FOUNDATION fieldbus H1
2 * IEEE 802.3 100BASE-TX / 10BASE-T (only ETH1 supported)
Connectors: RJ45
4 FF H1 links, compliant to type 114 of FF physical layer profile
(each link capable to operate independently as Link Master and/or Time Master)
Transfer rate: 31.25 Kbit/s
Fieldbus voltage range: 9 VDC ... 32 VDC, preferred voltage: 24 VDC
Current consumption: 10 mA / link
Connectors: 3-position screw connection, galvanically isolated
Physical Properties Dimensions (H x W x D)
Weight
Power Supply






Operating / Storage Temperature
Relative Humidity
Cooling
Coating
Mounting
Protection Class
100 mm x 35 mm x 105 mm
Approx. 0.25 kg
18 VDC ... 32 VDC; SELV/PELV power supply mandatory
Typical input current: 200 mA, maximum input current: 1 A (allowing for in-rush current at switch-on)
No power supply to FF H1 links through FG-200 HSE/FF Modbus
-40 °C .. +70 °C / -40 °C .. +85 °C
(see detailed mounting description in user manual)
10 % ... 95 %, non-condensing
Convection, no fan
Conformal coating based on ANSI / ISA-S71.04 G3
DIN rail 35 mm
IP20
Software Protocols


Redundancy
FOUNDATION fieldbus H1
FOUNDATION fieldbus HSE
Modbus TCP
Device redundancy compliant to type D-3 according to specification FF-593
Conformity / Certifications CE

Electromagnetic Compatibility (EMC)


Vibration / Shock

Hazardous Location Certifications


Safety Requirements
EN61000-6-2, EN61000-6-4, EN55022 Limit Class A, EN55011
FCC CFR45, Part 15 Section 15.107 and 15.109 (Class A),
VCCI Class A Information Technology Equipment 2002
DIN EN 60068-2-6 Vibration / DIN EN 60068-2-27 Shock
cULus: Class 1, Division 2, Groups A, B, C, D (in preperation)
IECEx: Ex nA [ic] IIC T4 Gc
ATEX: II 3G nA [ic] IIC T4 Gc
IEC/EN/UL 61010-1
IEC/EN/UL 61010-2-201 (with CB scheme)

Scope of Delivery

Hardware FG-200 HSE/FF Modbus
Software FF Configuration Tool, FDT CommDTM, PACTware on CD-ROM
Documentation Quick Startup Guide, User Manual on CD-ROM

Order Numbers

 

GCL-EK-024100 FG-200 HSE/FF Modbus
GCL-EK-024101 FG-200 HSE/FF Modbus, functionally identical design variant for use with R. STAHL bus-Carrier Series 9419 and Fieldbus Power Supply 9412 products

For training , please contact us

People looking at this product may be also interested in :

I am text block. Click edit button to change this text. Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.