newsletter

dataFEED OPC Suite

Nouvelle Version sur dataFEED OPC Suite v 5.22

la nouvelles version dataFEED OPC Suite v 5.22 est disponible.

Nouvelles fonctionalités :

  • OPC UA Reverse Connect ( Serveur & Client) : Ce n’est pas uniquement le Client qui se connecte au serveur, mais le Serveur qui peut également se connecter au Client. Cela permet de d’optimier la sécurité, si c’est le serveur qui doit se connecter. Pas de ports laissés ouverts. Sécurité accrue de votre installation.
  • Softing OPC UA SDK versoin 6.00 intégré
  • Softing OPC Classic SDK Version v4.31.21 intégré

OS supportés :

  • Windows 7, Windows 8, Windows 8.1, Windows 10, Windows 11
  • Windows Server 2008 R2, Windows Server 2012 R2, Windows Server 2016, Windows Server 2019, Windows Server 2022

Découvrez dès maintenant la nouvelle version du dataFEED OPC Suite…

 

improved production process

NEWS from the  11 /08 / 2021

Asset management for improved production processes

Fieldbuses in the process industry

Digital field devices deliver an ever-increasing amount of data that provides sound insights into plant condition and based on which modern asset management can be carried out. To ensure a continuous data flow beyond the analog measured value, digital communication protocols have become established in the process industry in addition to the analog 4..20 mA current loop. The three most important are HART, Foundation Fieldbus (FF) and PROFIBUS. While FF is widely used in the USA, PROFIBUS has become the fieldbus protocol of choice in the European process industry. It allows the long cable runs required in process automation and the PROFIBUS PA profile can be used in hazardous areas. And by supporting digital communication and manufacturer-independent device exchange, it offers the best conditions for controlling, monitoring and streamlining production processes.

Ethernet/IP for modern asset management

But fieldbuses are not the end of the story. Ethernet-based control systems are available for innovative asset management. They offer higher bandwidths for data transmission and enable the integration of Industry 4.0 applications. By integrating these PLCs, existing plants in the process industry can be expanded to include modern and highly functional segments.

Combined solutions manage the transition to state-of-the-art technology

This is where the combined solutions come in that Softing Industrial has developed with its partners Schneider Electric and Endress+Hauser:

Softing’s “epGate” connects PROFIBUS PA and DP devices from Endress+Hauser with the M580 Ethernet/IP control system and the Control Expert engineering tool from Schneider Electric. The benefits are obvious:

  • The required investment is manageable, since it is not the entire plant that has to be modernized. The existing PROFIBUS PA and DP segments can be integrated into a modern Ethernet/IP network architecture without any changes.
  • Gateway integration is done quickly, either by using the generated EDS (Electronic Data Sheet) file (exported from the Embedded Web Server) or through the Schneider Electric Advanced Generic DTM (Device Type Manager) installed by default in EcoStruxure™ Control Expert engineering tool.
  • The Asset Management of the field devices can be easily realized via FDT (Field Device Type) frame applications such as FieldCare from Endress+Hauser with an included CommDTM (Communication Device Type Manager).

I am text block. Click edit button to change this text. Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.

PROFINET Switch 8 Port, managed M12 – IP67

The managed PROFINET-Switch supports PROFINET according to Conformance Class B and offers transmission security through ring redundancy as an MRP client.

One of the most important functions of a PROFINET-Switch is the prioritizing of the PROFINET frame traffic in the machine network. The managed switch can differentiate whether the frame is a web query, an FTP file transmission, a media stream, or a PROFINET frame. In the case of a high transmission load, the important frames can thus be prioritized in order to prevent frame losses.
With a GSDML file you can integrate the switch into your automation environment in the usual way.
The supported PROFINET protocols, such as LLPD, DCP, or even diagnosis alarms, can be easily configured and administered.

With its protection class IP67 and temperature range from -40 °C to +75 °C, the PROFINET Switch 8 Port, IP67 is ideal for use in rough industrial conditions. The product is ideally suited for installation without a control cabinet and therefore offers a wide range of applications.

 

  • PROFINET Conformance Class B
  • Integration into the automation network with GSDML file
  • Quick and easy configuration and diagnostics via PROFINET and web interface
  • LLDP, DCP, SNMP, diagnostic alarms
  • Media Redundancy: MRP Client
  • port mirroring
  • Network statistics (frames, errors)
  • Managed switch with 8 x 100 Mbps M12 ports
  • Protection class IP67
  • Switch cabinet-less assembly possible

Technical advantages when using a PROFINET-Switch

  • Prioritizing of PROFINET frames
  • Assignment of a configuration via the device name
  • Neighborhood detection
  • Device exchange without programming device
  • Ring redundancy
  • Each port can be activated or deactivated
  • Diagnostic messages for network problems
  • Identification and maintenance data

With this variant of the managed PROFINET-Switch, you can connect up to 8 network participants in harsh environments, saving time and money.

General information
Order number 700-857-8PS01
Article name PROFINET-Switch 8-port, managed, IP67
Scope of delivery PROFINET-Switch 8-port, Quick Start Guide, GSDML-File
Dimensions (DxWxH) 24 x 62 x 190 mm
Weight Approx. 410 g
PROFINET interface (X1)
Number 8
Protocol PROFINET IO Device as per IEC 61158-6-10
Physical layer Ethernet
Transmission rate 10/100 Mbps
Connection M12 D-coded
Features Media Redundancy Protocol (MRP)
automatic addressing / topology detection (LLDP, DCP), conformance class B
Status indicator 3 LEDs, function status
16 LEDs, Ethernet status
Voltage supply (X2)
Voltage supply DC 24 V (18 … 30 VDC)
Connection M12 L-coded
Current draw Max. 130 mA at 24 V DC
Power dissipation Max. 3.5 W
Ambient conditions
Ambient temperature -40 °C … +75°C
Transport and storage temperature -40 °C … +85 °C
Protection rating IP67
Certifications CE
CE
RoHS Yes
REACH Yes

Documentation:

 

Software

  • PROFINET Switch, 4/8/16 Ports, GSDML file       (V9-2019 )

mbGate DP

Modbus TCP server to PROFIBUS DP Master

Simple connection of PROFIBUS DP Slave devices to Modbus control systems via internal I/O mapping

With mbGate DP it is possible to integrate one PROFIBUS DP segment into Modbus TCP control systems. It acts as Modbus TCP Server and PROFIBUS DP Master. With our gateways the engineering costs can be reduced since it re-uses existing PROFIBUS DP segment without the requiring modification. It enables simple configuration, parameterization and plant asset management using standard industry tools and is compatible with products of leading PLC Manufacturers.

Similar solutions:
mbGate PA: Modbus TCP to PROFIBUS PA Gateway – Integrate PROFIBUS DP segments into Modbus Control system
mbGate PB: Modbus TCP to PROFIBUS PA/DP Gateway – Integrate PROFIBUS DP/PA segments into Modbus Control Systems

Configuration, Parameterization and Plant Asset Management Using Standard Industry Tools

  • Supports major Modbus engineering tools such as Schneider Unity Pro or Siemens TIA Portal
  • Included CommDTM allowing use in FDT/DTM frame applications
  • EDD-based device parametrization using Siemens Simatic PDM

Direct Connectivity to PROFIBUS Segments

  • Single access point to PROFIBUS DP segment from Modbus TCP networks
  • Acting as Modbus TCP Server and PROFIBUS DP Master
  • Support of one PROFIBUS DP segment

Key Component for Transition to State-of-the-Art Technology

  • Re-use of existing PROFIBUS DP segment without requiring modification
  • Easy integration into PLC programming software
Scope of Delivery
Hardware mbGate DP Gateway
Documentation On Website
Order Numbers
GCA-EN-024806 mbGate DP, Modbus TCP to PROFIBUS DP Gateway. Supports 1 PROFIBUS DP segment (RS485).
Additional Products and Services
LRA-EN-024851 gatePlus HighAvailability. License for activating redundancy features in mbGate DP
LRL-DY-134501 dataFEED OPC Suite, Version 4.01 and higher, including all supported PLC protocols, support for OPC UA, access for any number of dataFEED OPC Tunnel Clients, for simultaneous access to a total of up to 100 OPC UA Servers, OPC Servers and OPC Tunnel Servers, and many more Functionalities such as Database and File Access, Data Exchange, Optimizer, Concentrator and Bridge
GCA-EL-024802 mbGate PA, Modbus TCP to PROFIBUS PA Gateway. Supports up to 2 PA segments (up to 32 PA devices).
GCA-EL-024804 mbGate PA, Modbus TCP to PROFIBUS PA Gateway. Supports up to 4 PA segments (up to 64 PA devices).
GCA-EN-024808 mbGate PB, Modbus TCP to PROFIBUS Gateway. Supports 2 PA segments (up to 32 PA devices, MBP physical layer) and 1 PROFIBUS DP segment (RS485).

WCT – X analyser – CAN analyser

X-Analyser 3 ( XA3) – The perfect CAN Analyser

What’s new into the X-ANalyser 3 ?

  • Graphical User Interface ideal for Windows PCs and tablets
  • CAN, J1939, NMEA2000, CANOpen, LIN and OBD – Included into one tool
  • T-Scripting, to make easier
  • On board Diagnostics scan Tool Features for emissions ECUs
  • CAN and LIN signal Reverse Engineering
  • Signales displays – Text, scope and graphical such as gauges and lamps
  • Can be used for ECU or even Network Simulation
  • SAE J1939 database integrated with over 4000 PGNs and signals
  • Supports industry standard log files and databases
  • Easy Project Sharing
  • Virtual networks and channels for off-line analysis

Warwick Control Technologies is a world leader in Controller Area Network (CAN) and related technology. It specialises in CAN,  CANopen, J1939, NMEA2000, LIN and FlexRay network technologies. We can also help you on the new fast CAN protocol (CAN-FD)

Our flagship product, the X-Analyser is a powerful, low cost Windows based tool that uses Kvaser, Peak or Vector interfaces to test your CAN/CANopen/J1939/NMEA2000/DeviceNet and LIN bus systems. It can also be used for OBD scan tool functions over the CAN bus, Click here to find out more.

CAN Gateway

  • X-Analyser includes a gateway component that can be used to duplicate frames from one CAN network on to another. This feature requires you to have two CAN channels configured in your project, you can then configure which channel to receive frames on and which channel to transmit them back out on.

CANOpen

  • X-Analyser has support for the CANopen higher layer protocol which is used for industrial automation and other off-highway applications. There are two main areas of support for which you must have the X-Analyser Professional edition; message/signal interpretation and message transmission.

Filter Editor

  • Use the filter editor to filter CAN frames on the Raw Data Trace they can be filtered by; Channel, Data, Data Length, Direction, Frame ID, Frame Type and Timestamp. These can be used with a combination of logic functions to define certain criteria for Filtering.

Gauges

  • With a CAN database loaded signals can be configured to show as gauges. With a combination of gauge styles available and gauge values can be defined such as; Min and Max values and Minor and Major Step Intervals.

Interactive Generator

  • The Interactive Generator (IG) allows the user to use a CANdb (*.dbc) file to interactively transmit CAN messages onto a system using the signals physical values that will automatically be converted to raw CAN data. Running in parallel with X-Analyser, the IG allows the user to create and change CAN messages on the fly. Transmission of a message can be carried out by user interaction (i.e. by clicking on a button) or by a timer with resolution 5ms which allows periodic transmitting.

ISO 1 5765 Mode 3 DTC’s

  • The ISO 15765 transport layer can be used to easily create a OBD Mode 3 request frame and also displays the response as Mode 3 DTC’s in Hexadecimal format.

ISO 1 5765 transmitter

  • Easily create a Mode 3 transmitter when the ISO 15765 Higher Layer Protocol has been added.

J1939 Signals Database

  • pic X-analyser Professional Edition comes with a J1939 database where signals can be selected and source address defined so they can be displayed in a Signals Panel, Gauge or Scope.

J1939 Signals

  • Within the J1939 Raw Trace tab available with X-analyser Professional CAN frames can be expanded to show the signals within that frame.

Object Transmitter

  • The Object Transmitter can be used to create CAN frames and transmit them onto a network. Standard and Extended ID’s can be selected, also Transmitters can be sent periodically by selecting Auto-Repeat and defining the time interval in milliseconds.

Scope

  • With a CAN database loaded signals can be selected for the scope to displayed and plotted. Points on the scope can be selected to show the value at a certain time. The scope can also be exported to CSV format to be opened and worked with in Excel.

Signal Editor

  • The signals editor can be used to create parts of a CAN database on the fly, what’s created can be configure to a signals panel, gauges or scope.

Signal Panel

  • With a CAN database loaded signals can be configured to the signals panel to show physical values. The signals can be displayed numerically or symbolically.

Signals search function

  • CAN databases when loaded can be searched using the signals search function. Quotation marks can also be used to search for a whole name i.e. “Engine RPM”.

Symbolic and Numeric values

  • X-analyser can now have the same signals displayed more than once on a signals panel, gauge or scope. Within a signals panel the same signal can be displayed more than once with each as a symbolic or numeric value.

UDS DTC Reader

  • X-analyser now has a UDS DTC reader, once configured in the transport protocol for the UDS DTC reader. It shall read and clear UDS DTC’s with the option to set the DTC Status Mask so different ECU’s can be read.

• Graphical User Interface ideal for Windows PCs and tablets.

• CAN, J1939, NMEA2000, CANopen, LIN and OBD – included into one tool

T-Scripting, to make life easier.

• On-Board Diagnostics Scan Tool Features for Emissions ECUs.

• CAN and LIN signal reverse engineering

• Signals displays – text, scope and graphical such as gauges and lamps

• Can be used for ECU or even network simulation

• SAE J1939 database integrated with over 4000 PGNs and signals

• Supports industry standard log files and databases

• Easy Project Sharing

• Virtual networks and channels for off-line analysis

For download, please contact us 

or email us at :  info@ca.atevatech.com

For training, please contact us  or email us at : info@atevatech.com

TCP/IP-H1-OPC-Server

TCP/IP-H1-OPC-Server

All-in-one OPC Server With Maximum Protocol Scope Via TCP/IP and H1 (Included in Former INAT Multi-Protocol OPC Server)

The TCP/IP-H1 OPC Server offers uniform access to the leading controllers of the companies Siemens, Rockwell Automation, Schneider Electric or Mitsubishi. This high-performance OPC Server is easy to configure and offers a wide variety of diagnostic capabilities.

Everything at a Glance

  • Functionality based on customer requirements
  • Ethernet protocol dependent on controllers and field devices
  • Reliable communication with control system

Application Area

  • Heterogeneous networks with controllers and devices from a wide variety of different manufacturers
  • Support of standard TCP/IP, Sinec H1, various serial protocols
  • Increased investment protection for integration of existing systems

Features

  • High-performance protocol for transmission of large amounts of data via OPC
  • No limit to number of connected controllers and variables
  • High degree of reliability for all OPC Clients with OPC interface V1.x and V2.05
  • Easy to commission via symbolic addressing (Alias Browsing)
  • Easy symbol import directly from STEP 7 project
  • Increased availability due to continuous line monitoring and extensive communication diagnostics
  • SNMP access to devices of different vendors via MIB Import and SNMP Browse

Supported Controllers Softing and Siemens CPs, Allen Bradley CLX, SLC and PLC 5 controllers, Mitsubishi Melsec-Q vontrollers, various Modbus TCP interfaces, SNMP devices
Supported Protocols See table
Supported Operating Systems Windows XP, Windows 7, Windows 8, Windows 8.1, Windows 10, Windows Server 2003, Windows Server 2008, Windows Server 2008 R2, Windows Server 2012, Windows Server 2012 R2, Windows Server 2016
Demo Version Full TCP/IP-H1 OPC Server functionality, time-limited to 72 hours
ATV-LRL-DY-131001 TCP/IP-H1 OPC Server, single license
ATV-UAC-DD-0100 USB hardware for replacing the software key required for activating a Softing product

Additional Products and Services

ATV-GPL-CS-191000 echolink S7-compact

Scope of Delivery

Software TCP/IP-H1 OPC Server on CD-ROM
Documentation Online Help in English and German

EZ Gateway Modbus to BACnet

EZ Gateway Modbus to BACnet

ez-knx-bac-top

The EZ Gateway Modbus to BACnet (FS-EZX-MOD-BAC) is an easy-to-use, high-performance building and industrial automation protocol gateway for integrators to interface Modbus devices, such as power meters, flow meters, and other Modbus-based controllers, to BACnet networks in commercial buildings, campuses, and industrial facilities. The EZ Gateway supports up to 1000 data points and can connect various flavors of Modbus to BACnet, including:

  • Modbus RTU
  • Modbus TCP/IP
  • BACnet/IP
  • BACnet MS/TP

The EZ Gateway is the quick and easy solution to a system integrator’s Modbus to BACnet integration needs. With the EZ Gateway, the integrator or contractor does not need to be a protocol expert to connect any Modbus device to a BACnet system using either BACnet protocol.

With our long-standing association with the Modbus Organization and total commitment to the Modbus standard, we consistently implement the latest Modbus innovations on our FieldServer protocol gateways and test them thoroughly for interoperability. With tested Modbus features like bit extracting, 32 bit float/integer support, and scaling, our EZ Gateway Modbus to BACnet can work with virtually any Modbus device out of the box. Instant interoperability means that there the devices can be commissioned quickly.

Unparalleled Performance

The EZ Gateway Modbus to BACnet has two RS-485 ports, enabling connection for fewer devices per port, which improves response time. With two RS-485 ports, up to 64 Modbus RTU devices can be connected to the EZ Gateway without the need of adding a repeater to the RS-485 network. Compared to single-port gateways, our dual-port EZ Gateway can reduce the cost of device connectivity or double the speed of connected devices.

The EZ Gateway can connect to 100 Modbus TCP/IP devices via Ethernet. In addition, support for Modbus TCP/IP Concurrent Polling on our EZ Gateway enables faster response time and more devices per segment in situations where the Modbus field devices also support concurrent polling.

1. SMC Device Cloud support

Register your EZ Gateway to the SMC Cloud interface for remote access to local applications, configuration, and device management

2. Modbus Features and Interoperability

Connect with virtually any Modbus device out of the box

  • Modbus Data Manipulation: Efficiently translate between Modbus and BACnet devices through bit extracting
  • Modbus TCP/IP Concurrent Polling: Receive faster response time and support more devices per segment
3. Modbus to BACnet EZ Profiles

Lower commissioning time by uploading preconfigured verified Modbus-BACnet EZ Profiles

4. DeviceProxy™

Minimize management and operational costs with granular visibility and control over each Modbus device from a BACnet management station

5. Dual RS-485 Ports

Improve response time by connecting fewer devices per port or support more devices per gateway

6. Remote Access and Support

All FieldServer gateways come with Remote Access support.  Once registerd to the SMC Cloud, use the Remote Access capability to attach to the FieldServer gateway to monitor, maintain and troubleshoot installed equipment

Model Numbers FS-EZ1-MOD-BAC: 500 point capacity
FS-EZ2-MOD-BAC: 1000 point capacity
Environment Operating Temperature: -40 to 75°C (-40 to 167°F)
Relative Humidity: 5-90% RH non-condensing
Power Requirements 9-30 VDC or 12-24 VAC
Current draw @ 12V:

  • FS-EZx-MOD-BAC: 240 mA
Enclosure Dimensions: 4.5 x 2.9 x 1.6 in. (11.5 x 7.4 x 4.1 cm)
Weight: 0.4 lbs (0.2 Kg)
Other Configuration/Diagnostic utilities
Table, wall, or DIN rail mount
Communication Baud: 4800, 9600, 19200, 38400, 57600, 115200
Start Bit: 7, 8
Stop Bit: 1, 2
Parity: Even, Odd, None
Ethernet: 10/100 BaseT MDIX
Approvals TUV Approved to UL 916, EN 60950-1, EN 50491-3 and CSA C22.2
standards
BTL Certifed, Rev. 12
RoHS Compliant
GOST-R Certified
CE and FCC

Communication Configurator

Universal Configuration Software for Industrial Ethernet and Fieldbus Networks

The Communication Configurator allows for easy configuration and commissioning of PROFINET and Foundation™ fieldbus (FF) networks. It is designed for working with products including Softing Industrial’s PROFINET Controller respectively Foundation™ fieldbus stack.

I am text block. Click edit button to change this text. Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.

csm_CommunicationConfigurator_D_EN_160601_200_4d37984c04

Fast Configuration Setting and Verification via Online Access

  • Windows-based tool with graphical user interface supporting extensive PROFINET and Foundation fieldbus configuration
  • Easy assignment of device properties via online access
  • Functional advantages like check of offline configuration against devices detected online
  • Early identification of discrepancies between offline configuration and real network situation
  • Integration of detected PROFINET network devices into existing configuration using station scans

Various Approaches to Network Configuration

  • Creation of device library by inserting and deleting device GSDML files as basis for configuration tasks
  • Access using various filter criteria
  • Division of major projects into multiple segments for easier handling, e.g. by supporting nested network structure
  • Support of offline and online configuration

Support of Application and Protocol Stack Integration for PROFINET Environment

  • Storage of configuration data in binary format for processing by other applications and transfer to Softing protocol software
  • Adaptation of I/O mapping implementation to individual engineering tool and application needs
PROFINET Configuration Functionality
  • Setting device names and IP addresses
  • Device reset to factory defaults
  • Blinking LED for device localization
  • Support of GSDML version V2.20 (Service Pack for GSDML version V2.25 available)
Foundation Fieldbus Configuration Functionality
  • Adding and removing of individual FF H1 Device Description files
  • Creation, storage, and deletion of individual configuration projects
  • Configuration of PC, FF HSE subnet, FF HSE field devices, Softing Linking Devices, FF H1 Link, and FF H1 field devices
  • Display of active devices in FF networks
  • Function Block linking and scheduling
  • Optional customer specific host systems, participation in FF HSE subnet
  • Fieldbus configuration data generation and checking
  • Download of configuration data to all devices or individual devices
  • Monitoring and changing of individual Function Block parameters online
Supported Operating Systems Windows 7 Professional / Enterprise / Ultimate, Windows 10
Supported Hardware for PROFINET Access FG-260 gateway
Supported Hardware for Foundation Fieldbus Access FG-200 gateways, FFusb interface board
Licensing Depending on Protocol Stack Licensing Model
Conformance Foundation Fieldbus: Host Integration System Test (HIST) requirements supported
ATV-VCL-YY-097701 Communication Configurator, standard license version
ATV-VCM-YY-097701 Communication Configurator, customized license version

Scope of Delivery

Software Communication Configurator
Documentation Tutorial, detailed user interface description in electronic format (PDF, CHM)

Additional Products and Services

ATV-CCM-AY-2000 PROFINET Controller Stack, one-off license fee
ATV-TRA-PN-TECH “PROFINET – Technology” training

BACNet Router

BACnet Router

Sierra Monitor’s BACnet Router (FS-ROUTER-BAC) product offers a complete BACnet internetworking solution for BACnet/IP, BACnet Ethernet, and BACnet MS/TP networks, while also providing a secure connection to the cloud.

Multiple BACnet routing connections can be established:

  • BACnet MS/TP to BACnet/IP
  • BACnet MS/TP to BACnet Ethernet
  • BACnet MS/TP to BACnet MS/TP
  • BACnet/IP to BACnet/IP
  • BACnet/IP to BACnet Ethernet

The FieldServer BACnet Router is available in two models: the dual-port version and the single-port version.

Accessing the BACnet Router Through FieldPoP

Enjoy the benefits of the cloud connectivity through FieldPoP™. The BACnet Router is FieldPoP-enabled, meaning all BACnet Routers can be registered to FieldPoP, Sierra Monitor’s device cloud for the IIoT.

The FieldPoP web interface lets users remotely access, in a secure fashion, the FS-GUI and configuration web applications that are available locally on the BACnet Router. These applications offer functionality for configuration, monitoring, logging, security, diagnostics, and updates.

Learn more about FieldServer and FieldPoP capabilities »

Innovative Features

The dual-port BACnet Router has two RS-485 ports, enabling connection to up to 64 BACnet devices without the use of additional line drivers. Using a BACnet router frees up valuable RS-485 ports on expensive BACnet Controllers and reduces the cost of connecting BACnet MS/TP devices to a BACnet/IP backbone. Compared to single-port BACnet routers, our dual-port BACnet router can reduce the cost of device connectivity or double the speed of connected devices (half the response time).

As our entry-level and cost-effective BACnet solution, the single-port BACnet Router has one RS-485 port, enabling connection to up to 32 BACnet devices without the use of additional line drivers.

DeviceFind™, our unique discovery feature, allows the integrator to discover all the BACnet devices connected to the router with one push of a button, minimizing time required for successful commissioning. Complementing this feature is our diagnostic FieldServer Toolbox, which allows the user or integrator to view the status of and diagnose all the routers on the network.

Easy to Install & Use

Our BACnet Router’s one page, set-and-forget configuration and unique network discovery capabilities minimize the integrator’s installation time. The fully compliant, top quality BACnet stack helps reduce troubleshooting time. An MDIX module makes it possible to use any Ethernet cable for commissioning and installation. DHCP automatically obtains IP settings from your network.

The BACnet Router includes NAT support with a secondary BACnet/IP connection for routing between public and private networks. A BACnet Broadcast Management Device (BBMD) allows for connection between different subnets. Familiar, web-based configuration makes the system easy to use.

Certifications & Approvals

Sierra Monitor’s BACnet Router is the first standalone device in the industry to carry the BTL (BACnet Testing Laboratories) mark. BTL certification ensures the highest standard of BACnet integration and assures users that they are utilizing a high-quality BACnet product. The BTL mark indicates that our router has passed a series of rigorous independent laboratory testing and verifies that the product fully implements the BACnet features claimed. In addition, the BACnet Router is RoHS compliant, TUV approved to UL-916, and CSA, CE and FCC approved.

TH LINK Modbus TCP

TH LINK for  Modbus TCP Protocol

csm_THLink_MBE_D_EN_160401_300_dd90bdfb7b

Modbus TCP Network Diagnostics Independent from Controller and Control Room

The TH LINK for Modbus TCP diagnostics tool makes use of a controller-independent access to monitor Modbus networks. The diagnostic data is collected in networks comprising up to 254 nodes, and made available to users through the TH SCOPE software application. TH LINK ModbusTCP is easy to use and can be integrated without interfering with the operation of existing installations.

Independent Access to Modbus TCP Network

  • Controller-independent
  • Independent of configuration tools
  • Only one tool needed to monitor multiple IP subnetworks (up to 254 nodes, one or more controllers)

Designed for Installation without Interference with Plant Operation

  • Connection to free port in Modbus TCP network, also possible during operation of the plant
  • No need to install TAPs or use mirror ports
  • Highest security (separate accesses for control room level and plant level, no routing)
  • Easy integration into existing plants thanks to compact design

Powerful Data Collection Capabilities Optimized for Modbus TCP

  • Collection from Modbus TCP devices and other nodes (e.g. PCs or camera systems)
  • Combination of active and passive measurements
  • Limitation of network load

Optimized for Use by Maintenance Engineers

  • Suitable for network acceptance testing, continuous monitoring and troubleshooting
  • Easy and intuitive handling and operation
  • Fault identification with intelligent troubleshooting assistance
  • Seamless integration with TH SCOPE diagnostics software
Functionality
  • Network detection and data collection
  • Alarm notification in case of fault
  • Basic monitoring, configuration
  • Integrated web server
Input Voltage 24 VDC (18 VDC … 32 VDC)
Current consumption max. 180 mA
Current consumption relay contact max. 100 mA
Operating Temperature -40 °C … +75 °C
Relative Air Humidity 5 … 95 % (no condensation)
Ethernet Ports RJ-45 (10Base-T/100Base-TX)
Supported SD Cards See Release Notes
Mounting 35 mm DIN rail
Dimensions (HxWxD) 22.5 x 99 x 114.5 mm
Weight 120 g
Certifications CE
GDA-JE-003036 TH LINK Modbus TCP

Scope of Delivery

Hardware TH LINK Modbus TCP
Documentation Installation Manual, Release Note (by download)

Additional Products and Services

LRA-JY-003024 TH SCOPE (software key)
LRL-JY-003025 TH SCOPE (hardware key)
LRA-JY-003028 TH LINK PC Industrial Ethernet (software key)
LRL-JY-003029 TH LINK PC Industrial Ethernet (hardware key)
GDA-JY-003037 TH LINK Industrial Ethernet