mobiLink Power : Single USB interface for PROFIBUS PA, HART, FOUNDATION fieldbus

mobiLink power enables a direct connection to the field device without it having to be located within a functioning bus infrastructure. The integrated power supply eliminates the need for additional components such as external power supply and terminating resistors for commissioning and maintenance of the field devices.

Single interface for the major Process Automation protocols

  • HART Master, Foundation Fieldbus Host and PROFIBUS PA Master included in one device
  • Parametrization and configuration of field devices
  • Diagnostics and condition monitoring

mobiLink Power presentation ( PDF )

Provides the power supply for the field devices

  • Eliminates the need for an additional power supply and power conditioner for workbench applications

Support of FDI, FDT frame applications and major engineering tools

  • PACTware FDT frame application and HART communication DTM included
  • Communication DTM for Foundation Fieldbus and PROFIBUS PA (optional)
  • Foundation Fieldbus configuration tool (optional)
  • Application Program Interface for integration into engineering systems

Unlimited flexibility in use

  • mobilink Power draws power from the connected computer via USB

Please find this product into our renting product

DUA-KM-020440 mobiLink Power for HART applications, including accessories
LRA-KK-021973 linkPlus FF – License to activate Foundation Fieldbus
LRA-LL-021974 linkPlus PA – License to activate PROFIBUS PA
LRA-KK-020721 Licence for FF Configuration Tool ComConf

You may also be interested in :

pnGate PA

PROFINET to PROFIBUS PA Gateway (pnGate PA)

Direct PROFIBUS PA Segment Integration into PROFINET Control Systems

  • Re-use of Existing Power Conditioners in Technology Upgrade Projects
  • No PROFIBUS DP Intermediate Segment required
  • Prepared for Integration in Standard Engineering and Plant Asset Management Tools

Key Component for Transition to State-of-the-Art Technology

  • Simple replacement of installed PROFIBUS DP/PA segment couplers
  • Re-use of existing PROFIBUS PA segments without requiring modification
  • Support of PROFINET redundancy for increased reliability

Direct Connectivity to PROFIBUS Segments

  • Acting as PROFINET Device and PROFIBUS PA Master
  • Support of up to 4 PROFIBUS PA segments

Configuration, Parameterization and Plant Asset Management Using Standard Industry Tools

  • Supports major PROFINET engineering tools such as TIA Portal, Step7 and PC WORXS
  • Included CommDTM allowing use in FDT/DTM frame applications
  • EDD-based device parametrization using Siemens Simatic PDM
Technical Details
Hardware Processor
Status LEDs (Gateway)Status LEDs (Fieldbus)
Altera Cyclone V SoC with dual-core ARM Cortex-A9
PWR (power supply), RUN (operation), ERR (error), CFG (configuration and update)
SF (system fault), BF (bus fault)
Interfaces and Connectors Ethernet

PROFIBUS PA

2 * IEEE 802.3 100BASE-TX / 10BASE-T, embedded PROFINET switch for daisy chain topology
Connectors: RJ45
Protocol: PROFINET RT / IRT, Support of PROFINET redundancy protocols
RESTful API interface for device configuration
Up to 4 PROFIBUS PA (MBP) segments (refer to the section “Order Numbers”),
Bus-powered Medium Attachment Unit (MAU): Fieldbus voltage range: 9 VDC … 32 VDC,
current consumption 10 mA,
Connectors: 3-position screw connection, galvanically isolated
Physical Properties Dimensions (H x W x D)
Weight
Power SupplyOperating / Storage Temperature
Relative Humidity
Cooling
Coating
Mounting
Protection Class
100 mm x 35 mm x 105 mm
About 0.25 kg
18 VDC … 32 VDC; SELV/PELV power supply mandatory
Typical input current: 200 mA, maximum input current: 1 A (allowing for in-rush current at switch-on)
No power supply to PROFIBUS PA segments through pnGate PA
-40 °C … +70 °C / -40 °C … +85 °C
(see detailed mounting description in user manual)
10 % … 95 %, non-condensing
Convection, no fan
Conformal coating based on ANSI / ISA-S71.04 G3
DIN rail 35 mm
IP20
Scope of Delivery
Hardware pnGate PA Gateway
Software GSDtoGSDML Converter, FDT CommDTM, PACTware, Drivers and Tools
Documentation On CD-ROM
Order Numbers
GCA-AL-024602 pnGate PA, PROFINET to PROFIBUS-PA Gateway. Supports up to 2 PROFIBUS PAsegments (up to 32 PA devices).
GCA-AL-024604 pnGate PA, PROFINET to PROFIBUS-PA Gateway. Supports up to 4 PROFIBUS PAsegments (up to 64 PA devices).
GCA-AL-024605 pnGate PA (for STAHL carrier), PROFINET to PROFIBUS-PA Gateway. Supports up to 4 PROFIBUS PA segments (up to 64 PA devices). For reversed mounting position on STAHL backplane.
Additional Products and Services
GCA-AN-024608 pnGate PB, PROFINET to PROFIBUS Gateway. Supports up to 2 PROFIBUS PAsegments (up to 32 PA devices, MBP physical layer) and 1 PROFIBUS DP segment (RS485).
GCA-EL-024802 mbGate PA, Modbus/TCP to PROFIBUS-PA Gateway. Supports up to 2 PROFIBUS PA segments (up to 32 PA devices).
GCA-EL-024804 mbGate PA, Modbus/TCP to PROFIBUS-PA Gateway. Supports up to 4 PROFIBUS PA segments (up to 64 PA devices).

mobiLink Interface

Mobile Interface for HART, FOUNDATION fieldbus, Profibus PA

csm_mobiLink_5ff21a0363

mobiLink is a both Bluetooth and USB solution for commissioning parameterization & maintenance for field devices

  • Single interface for the major Process Automation protocols: HART / Foundation fieldbus / PROFIBUS PA
  • Perfectly suited for handheld host devices due to battery powered Bluetooth operation
  • Compatible with FDT Frame Applications
  • Approved for use in hazardous areas

Multi protocol operation available on mobiLink

  • HART Master, Foundation fieldbus Host and PROFIBUS PA Master  included in one device
  • Temporary attachment to fieldbus segments or HART loops for individual interaction with field devices
  • Fully compliant protocol implementations allow for interference-free access to running plants

Host communication via Bluetooth or USB

  • Built-in batteries and Bluetooth communication enable use of handheld host devices like smart phones and tablets
  • USB interface for bench host operation

mobiLink support of FDT Frame Applications and major Engineering Tools

  • PACTware FDT Frame Application and HART Communication DTM included
  • Communication DTM for Foundation fieldbus and PROFIBUS PA (optional)
  • Foundation fieldbus configuration tool (optional)
  • Application Program Interface for integration into Engineering Systems

Suitable for use in hazardous areas

  • The mobiLink is EX approval for Zone 1
  • Suitable for connection to intrinsically safe circuits
  • Suited for harsh environment
User Interface Controls
Status LEDs
Power on/off button, Bluetooth pairing button
FIELDBUS (Fieldbus mode), HART (HART mode), Bluetooth (Pairing/Bluetooth active), Low battery, Power on
Interfaces and Connectors USB

Bluetooth

Fieldbus

HART

Speed: USB 2.0 Full Speed
Connector: USB Type C
Electrical: Non intrinsically safe. Do not use inside hazardous areas.
5V, 100mA. Um = 253VBT mode: BT Classic, 2.4 – 2.478 GHz Output Power: +8 dBm (maximum)Connection: 4 mm banana type jacks (red/black), polarity has to be observed
Physical Layer: according to IEC 61158-2, Type 1: 31.25 Kbit/s, voltage mode
Nominal input current (Fieldbus):
10 mA in Bluetooth and regular USB mode
18 mA (with Ufieldbus > 9,5V) for increased battery life time in USB mode (controlled by application)
Fieldbus Terminator: No fieldbus terminator includedConnection: 4 mm banana type jacks (red/black)
Physical Layer: HART FSK compliant modem
Operation in Hazardous Areas Intrinsic Safety Parameters EX ia IIB, Ui = 30 V or FISCO field device
Isolation: 1500 VDC between USB and Fieldbus, 1500 VDC between USB and HART
Physical Properties Dimensions (L x W x D)

Weight

Power Supply

Operating Temperature

Storage

Relative Humidity

Protection Class

175 mm x 74 mm x 32 mm

330 g (incl. Batteries)

Battery: 3 * Alkaline, IEC-LR6, nominal voltage 1,5V
For use in hazardous area: Energizer E91 or Duracell Procell MN1500.
With batteries of other types or manufacturers certification is void.
Fieldbus interface (Medium Attachment Unit) powered by fieldbus.

-20°C .. +50°C

Store batteries in a dry place at normal room temperature.

< 95% rH non condensing

IP 54 (if USB port covered with cap)

Scope of Delivery
Hardware mobiLink, USB cable, fieldbus cable set with clips, 3 * Alkaline IEC-LRC6, USB memory stick
Software PACTware, Communication DTM for HART, Foundation Fieldbus and PROFIBUS PA (for Foundation Fieldbus and PROFIBUS PA optional license required)
Foundation Fieldbus Configuration Tool ComConf (optional license required)
Documentation On USB memory stick
Order Numbers
DBA-KM-020410 mobiLink for HART applications
LRA-KK-021971 Licence for FF CommDTM
LRA-NN-021972 Licence for PA CommDTM
LRA-KK-020721 Licence for FF Configuration Tool ComConf
DBL-KM-020411 mobiLink HART incl. FF Comm DTM Licence
DBL-KM-020412 mobiLink HART incl. FF and PA Comm DTM Licenc

How to connect with Foundation Fieldbus devices via mobiLink:

How to connect with Foundation Fieldbus devices via mobiLink:

How to change Foundation Fieldbus node addresses:

People interested in this product, are also interested in :

TH Link PROFIBUS

TH Link PROFIBUS

Plant Asset Management with optional monitoring for PROFIBUS Networks

Access to PROFIBUS networks for any FDT frame application, Emerson’s AMS and Softing’s TH SCOPE

THLINK PROFIBUS provides controller-independent access to PROFIBUS networks for plant operation and maintenance staff. The tool supports both plant asset management applications and network diagnostics. THLINK PROFIBUS is easy to be integrated without interfering withthe operation of existing installations.

Independent Access to PROFIBUS Network

  • Controller-independent
  • Independent of configuration tools
  • Access for plant asset management applications to configure field devices based on FDT/DTM and EDDL standards (acyclic master)

Designed for Installation without Interference with Plant Operation

  • Connection to PROFIBUS network also possible during operation of the plant
  • Easy integration into existing plants thanks to compact design
  • Browser access for administration and configuration purposes

Powerful Data Collection Capabilities Optimized for PROFIBUS

  • Passive listening to PROFIBUS DP protocol
  • Threshold monitoring for frame retries
  • Statistics for optimization of the network configuration
  • Easy detection of missing terminating resistors

Optimized for Use by Maintenance Engineers

  • Central and time-saving parameterization of PROFIBUS and HART field devices directly from the control room
  • Continuous monitoring and troubleshooting for PROFIBUS networks
  • Fault identification with intelligent troubleshooting assistance
  • Seamless integration with TH SCOPE diagnostics software
Functionality
  • Network detection and data collection (PROFIBUS DP)
  • Acyclic master (PROFIBUS DP-V1)
  • Alarm notification in case of fault
  • Basic monitoring, configuration
  • Integrated web server
Supported Plant Asset Management Applications e.g.:

  • Endress+Hauser FieldCare
  • Emerson AMS Suite
  • Yokogawa Fieldmate
  • PACTware
PROFIBUS Transmission Rate
  • max. 12 MBit/s (AMS Device Manager, FDT)
  • max. 1.5 MBit/s (TH SCOPE)
Input Voltage 24 VDC (19.2 VDC … 28.8 VDC)
Current consumption max. 190 mA
Operating Temperature 0 °C … 50 °C
PROFIBUS interface RS 485
Ethernet Port RJ-45 (10Base-T/100Base-TX)
Mounting 35 mm DIN rail
Dimensions (H x W x D) 22.5 x 99 x 114.5 mm
Weight 120 g
Certificate CE
  • ATV-GEA-JN-003006 TH LINK PROFIBUS

    Scope of Delivery

    Hardware TH LINK PROFIBUS
    Documentation Installation Manual, Release Notes (by download)

    Additional Products and Services

    ATV-LRA-JY-003024 TH SCOPE (software key)
    ATV-LRL-JY-003025 TH SCOPE (hardware key)
    ATV-LRA-NN-021980 DTM Library
    ATV-VAA-YY-023000 PACTware
    ATV-VAA-NM-023001 TACC

PACTWARE

PACTware

Operating Software for Configuration and Parameterization of Field Devices (FDT/DTM)

Designed for the efficient and fieldbus-independent operation of Field Device Tool (FDT) / Device Type Manager (DTM)-based field devices from a wide variety of manufacturers, PACTware provides an easy and cost-effective solution for getting started with plant asset management applications. PACTware also allows fieldbus diagnostics and the simulation of operating states.

Easy and Cost-Effective Way to Get Started with Plant Asset Management Applications

    • Easy central operation of field devices from different manufacturers
    • Fieldbus-independent use with the corresponding CommDTMs
    • FDT/DTM standard compliant
    • Software application available free of charge

Efficient Use of Field Devices in the Process Industry

  • Fast plant commissioning, fast replacement of defective devices
  • Simple remote device parameterization
  • Comprehensive monitoring of process-critical devices
  • Central management of all device parameters
  • Automatic creation of plant documentation
Functionality
  • Creating and opening projects
  • Connection between DTM and device
  • Data exchange between DTM and device
  • Editing of device data with the DTM
  • Device catalog
  • Project view
  • Plant view
  • Debug and error monitor
Network Access PROFIBUS
  • TH LINK PROFIBUS
  • PBPro-USB
  • PBpro ETH
  • PBpro PCI
  • PBpro PCI Express
  • PBpro CompactPCI
  • PBpro PC104plus
  • PROFI104
FOUNDATION™ fieldbus
  • FG-200 FF
  • FFusb
Supported Operating Systems Windows Vista, Windows 7, Windows 8
System Requirements
  • Microsoft .NET Framework 2.0
  • Adobe Reader 8.0 or higher for reading the documentation
  • 50 MB free hard disk space
  • 40 MB RAM
VAA-YY-023000 PACTware (free of charge)

Scope of Delivery

Software PACTware (developed by members of the PACTware Consortium)
Documentation User Manual

Additional Products and Services

GEA-JN-003006 TH LINK PROFIBUS, CommDTM available via DTM Library
LRA-NN-021980 DTM Library
PB-USB PROFIusb, including CommDTM
DEL-NN-012311 PBpro ETH, single-channel (different versions), including CommDTM
PB-PRO1-PCI / PB-PRO1-PCI/LP1 PBpro PCI Master/Slave, single-channel, including CommDTM
PB-PRO1-PCIE / PB-PRO1-PCIE/LP1 PBpro PCI Express Master/Slave, single-channel (different versions), including CommDTM
PB-PRO1-CPCI PBpro PROFIBUS CompactPCI interface card, including CommDTM
PB-PRO1-PC104+ PBpro PC/104plus card (different versions), including CommDTM
PB-PC104-MS PROFI104 Master/Slave (different versions), including CommDTM
GLA-YK-020110 FG-110 FF, including CommDTM
DUA-KK-020300 FFusb, including CommDTM

People having seen this page can be interested in :

DTM Libraries

DTM Libraries – Libraries for Siemens DP/PA Links

ET 200M, ET 200SP and PROFIBUS DP v1

Extended Field Device Access for Plant Asset Management Applications (FDT/DTM)

The DTM Library provides central access to PROFIBUS DP, PROFIBUS PA and HART field devices for plant asset management applications. The library also includes Communication Device Type Managers (CommDTMs) for the Siemens components DP/PA Link, ET 200M and ET 200iSP. Combined with TH LINK PROFIBUS, the solution can additionally be used to monitor the PROFIBUS network

Increased Efficiency Through Use of Plant Asset Management Applications

  • Fast plant commissioning, fast replacement of defective devices
  • Simple remote device parameterization
  • Central management of all device parameters
  • Comprehensive monitoring of process-critical devices
  • Automatic creation of plant documentation

Standardized FDT/DTM-Compliant Architecture

  • Communication with field devices via PROFIBUS DP, PROFIBUS PA and HART
  • CommDTMs for access to Siemens components DP/PA Link, ET 200M, ET 200iSP
  • Flexible integration into most common plant asset management applications (such as Endress+Hauser  FieldCare, Emerson AMS Suite, Yokogawa Fieldmate, PACTware)

Additional Benefit From Integrated PROFIBUS Monitoring

  • Use of TH LINK PROFIBUS for simultaneous PROFIBUS diagnostics
  • Threshold monitoring for frame retries
  • Statistics for optimization of the network configuration
  • Easy detection of missing terminating resistors

Flexible, Expandable Complete Solution

  • Getting started with plant asset management, e.g. using PACTware, with possibility of later adding further asset management applications
  • TH LINK PROFIBUS optionally expandable by TH SCOPE diagnostics software
Supported Hardware CommDTM PROFIBUS DP-V1
CommDTM DP/PA Link
CommDTM ET 200M
CommDTM ET 200iSP
TH LINK PROFIBUS
SIMATIC DP/PA Link
SIMATIC ET 200M
SIMATIC ET 200iSP
Functionality
  • Access to PROFIBUS PA and HART devicesAdditionally for CommDTM PROFIBUS DP-V1:
  • Integrated bus parameter test ensuring reliable non-reactive parameterization
  • Automatic scan of the PROFIBUS network
  • Frame logging for analysis of acyclic communication between control and field devices
Recommended PROFIBUS Access TH LINK PROFIBUS
Supported Plant Asset Management Applications Field Device Tool (FDT) frame applications compliant with FDT Specification 1.2 with Addendum, e.g. Endress+Hauser FieldCare, Emerson AMS Suite, Yokogawa Fieldmate, PACTware
Supported Operating Systems Windows 7 (English and German, 32 Bit and 64 Bit), Windows 8.1 (English and German, 32 Bit and 64 Bit), Windows Server 2012 R2
System Requirements Adobe Reader 8.0 or higher for reading the documentation
Licensing Complete DTM Library or single CommDTMs
If TH LINK PROFIBUS is used, the CommDTM PROFIBUS DP-V1 is free of charge.
Automatic licensing by Endress+Hauser frame application
Activation of the complete DTM Library provides parallel PROFIBUS access via multiple gateways or interface cards; activation of the PROFIBUS DP-V1 CommDTM supports PROFIBUS access via a single gateway or interface card.
Certifications All CommDTMs of the DTM Library have been certified by an accredited test and certification laboratory of the FDT Group.

Downloads

  • Data Sheets

  • Drivers & Software

    • DTM Library V5
      • SIEMENS DTM Libraries for PROFIBUS DPv1, DP/PA Link, ET 200M and ET 200SP.
    • PACTware

      • Framework of PACTware Consortium e. V. for use of FDT 1.2, FDT 1.2.1 or FDT 2 compatible DTMs of individual manufacturers.
ATV-LRA-NN-021980 DTM  Librairies ( package including  CommDTMs)

Scope of Delivery

Software DTM Library (by download)
Comprising CommDTM PROFIBUS DP-V1, CommDTM Siemens DP/PA Link, CommDTM Siemens ET200M, CommDTM Siemens ET 200iSP
CommDTMs can be used individually
Documentation Installation Guide, User Manuals for all CommDTMs, Release Note (by download)

Additional Products and Services

ATV-GEA-JN-003006 TH LINK PROFIBUS
ATV-VAA-YY-023000 PACTware

Customers having looked for this product may be interested in the following one.

PBpro-USB

PBPro-USB : PROFIBUS USB interface

PBPro-USB

Universal PROFIBUS Interface with USB High Speed

High performance PROFIBUS USB interface for a wide variety of tasks from network configuration and device parameterization to plant maintenance and production data acquisition.

Handy Companion for Mobile Use

  • Matchbox-sized PROFIBUS interface
  • Always at hand – easily fits in any laptop bag
  • High-retention USB connector ensures reliable USB cable connection

Wide Area of Application

  • Device parameterization via FDT/DTM
  • Integrated with numerous parameterization and asset management systems
  • PROFIBUS connection for PC-based measurement and monitoring systems
  • Quick and easy PROFIBUS connection for applications such as SCADA or MES

Quick and Easy Installation

  • Simple connection via USB cable
  • Powered by USB, no external power supply required
  • Highly integrated hardware encased in a PROFIBUS connector supporting direct attachment to the PROFIBUS segment, thus avoiding interferences caused by reflections
  • Same driver setup and API as for all other Softing PROFIBUS interfaces
  • Support of various Microsoft operating systems, including Windows 10

Efficient Integration

  • Free PROFIdtm PROFIBUS Communication DTM supporting parameterization of PROFIBUS devices by FDT tools
  • Commented sample programs for easy use of the PROFIBUS application programming interface (API) in customer applications
  • Quick and easy integration of OPC Client applications via optional PROFIBUS OPC Server
  • Connectivity with Emerson’s AMS for access to HART devices via a PROFIBUS network using Softing’s free TACC software
PROFIBUS Protocol • PROFIBUS DP-V0 Master
• PROFIBUS DP-V1 Master: acyclic C2 Services
Fieldbus Connection 9-pin D-Sub connector
Transfer Rates 9.6; 19.2; 45.45; 93.75; 187.5; 500; 1500; 3000; 6000; 12000 kbps
PC Interface USB 2.0, High Speed (480 Mbps)
Status LEDs Multicolored LED indicators for PROFIBUS and USB
Operating Temperature 0 ºC .. +60 ºC
Storage Temperature -20 ºC .. +70 ºC
Relative Humidity < 90%, non-condensing
Housing Metalized plastic
Dimensions 64 mm x 40 mm x 17 mm
Power Supply Supply voltage: 5 V via USB
Current consumption: typically 350 mA (USB)
Drivers available for Windows XP, Windows 7, Windows 8, Windows 10
Conformity FCC VCCI

DUL-NN-012410

PBpro USB

Scope of Delivery

Hardware PBpro USB hardware, USB cable
Software Drivers, Sample programs on CD-ROM
Documentation On CD-ROM

Additional Products and Services

OPC-PB PROFIBUS OPC Server for DP-V0/DP-V1

PROFIBUS Training course available on demand

People having seen this page can be interested in :

FG-200 HSE/FF Gateway

Modbus TCP/FF HSE to FOUNDATION Fieldbus H1 Gateway

Integration of up to 4 FF H1 segments into control systems via Modbus TCP or FOUNDATION Fieldbus HSE

FF Network Integration via Modbus Including Redundancy

With Softing’s FG-200FF, you can easily integrate up to four FOUNDATION™ Fieldbus (FF) H1 links into control systems supporting Modbus. The Softing FG-200FF provides redundancy and is suitable for use in ATEX zone. This device features fast access to process data, while making use of Fiedbus Foundation (FF) advantages like reduced cabling, central field device parameterization, comprehensive diagnostics, or intrinsically safe device segments. The Fieldbus foundation gateway (FG-200FF) is fully compatible with the R. STAHL bus-Carrier Series 9419 and Fieldbus Power Supply Series 9412 products for a very easy commissioning.

Easy Commissioning with the FG-200FF

  • Optional support of R. STAHL bus-Carrier Series 9419 and Fieldbus Power Supply 9412 products (cabling reduced to a minimum)
  • Modbus data import to web server reducing mapping efforts

Easy Asset Management thanks to the FG-200FF

  • Visitor mode avoiding interference with network behavior
  • Enabling asset management systems (e.g. Emerson’s AMS) and Field Device Tool (FDT) frame applications (e.g. SMART VISION, FieldMate, Field Device Manager, FieldCare, or PACTware)

The FG-200FF gateway makes easy the device redundancy

  • Redundancy link enabling device redundancy (D-3 according to FF-593)
  • Automatic mirroring of configuration data
  • Very fast redundancy switch-over between 2* FG-200FF Fieldbus foundation Gateway

All Necessary Tools Included

  • FF Configuration Tool for configuration of devices and cyclic communication
  • PACTware for device configuration and basic asset management tasks

FG-200FF vs FG-100FF

FG-110 FG-200
CPU PowerPC 805T 100 MHz Cortex A9 400 MHz
H1 Interface (MAU) Inductive coupling (no bus power required) Bus-powered (10 mA drawn from bus)
Ethernet Ports 1 2 (medium redundancy, same IP address)
Redundancy Communication Serial Link (115,2 kBit/s) and Ethernet Serial Link (1 MBit/s) only, no load on Ethernet
Cabling All connectors on front side Fieldbus: bottom
Ethernet: front
Power: top or power bus in DIN rail
Mechanical Compatibility STAHL bus carrier
Dimensions 131 mm x 47 mm x 111 mm 100 mm x 35 mm x 105 mm (- 46%)

Compatibility

Functionality Comments
Host Interface
Device Interface
Engineering Existing projects can be downloaded without any changes
Mechanical Dimensions Smaller in each dimension: Same cabinet can be used
Bus Power Supply 10 mA required per Link (same as for all devices and most host systems)
FISCO Power Supplies with separate host interface must provide 10 mA on host side
Cabling Different positions, different connectors: Cables have to be modified
Redundancy Management FG-100/FG-110 and FG-200 cannot cooperate as redundant pair: No replacement of FG-110 by FG-200 in run possible. Complete redundant pair of Linking Devices has to be replaced at same time.
Hardware Processor
Status LEDs (Gateway)

Status LEDs (Fieldbus)
Altera Cyclone V SoC with dual-core ARM Cortex-A9
PWR (power supply), RUN (operation), ERR (error), RDL (redundancy link)
FF H1 activity per link
Interfaces and Connectors Ethernet


FOUNDATION fieldbus H1
2 * IEEE 802.3 100BASE-TX / 10BASE-T (only ETH1 supported)
Connectors: RJ45
4 FF H1 links, compliant to type 114 of FF physical layer profile
(each link capable to operate independently as Link Master and/or Time Master)
Transfer rate: 31.25 Kbit/s
Fieldbus voltage range: 9 VDC ... 32 VDC, preferred voltage: 24 VDC
Current consumption: 10 mA / link
Connectors: 3-position screw connection, galvanically isolated
Physical Properties Dimensions (H x W x D)
Weight
Power Supply






Operating / Storage Temperature
Relative Humidity
Cooling
Coating
Mounting
Protection Class
100 mm x 35 mm x 105 mm
Approx. 0.25 kg
18 VDC ... 32 VDC; SELV/PELV power supply mandatory
Typical input current: 200 mA, maximum input current: 1 A (allowing for in-rush current at switch-on)
No power supply to FF H1 links through FG-200 HSE/FF Modbus
-40 °C .. +70 °C / -40 °C .. +85 °C
(see detailed mounting description in user manual)
10 % ... 95 %, non-condensing
Convection, no fan
Conformal coating based on ANSI / ISA-S71.04 G3
DIN rail 35 mm
IP20
Software Protocols


Redundancy
FOUNDATION fieldbus H1
FOUNDATION fieldbus HSE
Modbus TCP
Device redundancy compliant to type D-3 according to specification FF-593
Conformity / Certifications CE

Electromagnetic Compatibility (EMC)


Vibration / Shock

Hazardous Location Certifications


Safety Requirements
EN61000-6-2, EN61000-6-4, EN55022 Limit Class A, EN55011
FCC CFR45, Part 15 Section 15.107 and 15.109 (Class A),
VCCI Class A Information Technology Equipment 2002
DIN EN 60068-2-6 Vibration / DIN EN 60068-2-27 Shock
cULus: Class 1, Division 2, Groups A, B, C, D (in preperation)
IECEx: Ex nA [ic] IIC T4 Gc
ATEX: II 3G nA [ic] IIC T4 Gc
IEC/EN/UL 61010-1
IEC/EN/UL 61010-2-201 (with CB scheme)

Scope of Delivery

Hardware FG-200 HSE/FF Modbus
Software FF Configuration Tool, FDT CommDTM, PACTware on CD-ROM
Documentation Quick Startup Guide, User Manual on CD-ROM

Order Numbers

 

GCL-EK-024100 FG-200 HSE/FF Modbus
GCL-EK-024101 FG-200 HSE/FF Modbus, functionally identical design variant for use with R. STAHL bus-Carrier Series 9419 and Fieldbus Power Supply 9412 products

For training , please contact us

People looking at this product may be also interested in :

I am text block. Click edit button to change this text. Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.

PB-PRO1-PCIE

Universal PCI Express Boards for Use as Master or Slave

Single and dual channel interface boards in PCI Express format ( PB-PRO1-PCIE) for integrating PCs into PROFIBUS architectures as machine controllers, supervisory control applications, field devices or operator panels.

Support of PROFIBUS Master or Slave Functionality

The protocol required for the specific use case is user selectable and executed on the PB-PRO1-PCIE board. As a DP slave, the board integrates the PC into overlying control architectures. Configured as a DP master, the board turns the PC itself into the controller. As a DP Master Class 2, it provides the basis for parameterization and asset management tasks. In addition, integration into FMS systems or proprietary applications is just as easy and unproblematic as direct access at the lowest protocol level (FDL). This makes the PBpro PCI Express a universal interface solution and allows manufacturers to optimize the overhead costs and the inventory for their PROFIBUS options.

Rapid Integration With the Right Software Interface

The included PROFIBUS driver software is complemented with many sample programs that demonstrate how to use the PROFIBUS API. Commented sample programs show how this is done. A matching Softing OPC Server, which is available as an optional standard interface, quickly and easily connects any application that has an integrated OPC client. Typical applications include visualization, SCADA or MES systems. FDT compliant parameterization tools use the PROFIdtm Communication DTM from Softing as a link to the PB-PRO1-PCIE board. Used with the free STEP7 driver, the board can also provide a PG/PC adapter for programming Siemens controllers.

Application in a Wide Variety of Target Systems

In addition to standard Windows environments, the PBpro PCI Express board also supports Windows CE.NET as a real-time environment. On request, Softing’s team of engineers can customize the board according to customer specifications.

Master/Slave, Single Channel 1)  Slave, Single Channel 1) Master/Slave, Dual Channel
PROFIBUS Protocol
DP-V0 Master
DP-V1 Master: Acyclic C2 Services
FMS
FDL
DP-V0 Slave
Fieldbus Connection 9-Pin D-Sub Female, RS485, Galvanically Isolated
Transfer Rates 9.6; 19.2; 45.45; 93.75; 187.5; 500; 1500; 3000; 6000; 12000 Kbit/s
PC Interface PCI Express x1 According to PCIe r1.0a and CEM 1.1, 512 KB Shared RAM per Channel
Operating Temperature 0 oC .. +55 oC
Storage Temperature -20 oC .. +70 oC
Relative Humidity < 90%, Non-Condensing
Dimensions [mm] 168 x 69  168 x 69 168 x 103
Power Supply
Supply Voltage 3.3V / 12V (± 5%) DC
Current Consumption [mA] typ. 500 / 90 typ. 500 / 90 typ. 640 / 170
Drivers available for Windows 2000, Windows XP, Windows Vista, Windows 7, Windows 8, Windows 10
Conformity
PB-PRO 1-PCIE (PB-PRO 1-PCIE/LP1)) Master/Slave, Single Channel 1)
PB-PRO 1S-PCI E(PB-PRO 1S-PCIE/LP1)) Slave, Cingle Channel 1)
PB-PRO 2-PCIE Master/Slave, Dual Channel

Scope of Delivery

PC interface Board, CD with Drivers, Documentation and Sample Programs

Additional Products and Services

OPC-PB PROFIBUS OPC Server for DP-V0 / DP-V1
DCF-DY-4100 OPC Server for S7 / S5
TRA-PB-TECH PROFIBUS Technology Training

1) Also Available with Low Profile Slot Bracket

PB-PRO1-PCI

PB-PRO1-PCI

Universal PCI Boards for Use as Master or Slave. Single and dual channel interface boards in universal PCI format for integrating PCs into PROFIBUS architectures as machine controllers, supervisory control applications, field devices or operator panels.

csm_PBproPCI_D_EN_160801_201_a68cf76cc9

Always the Fitting PROFIBUS Protocol

  • PROFIBUS Master and Slave functionality
  • Support of PROFIBUS DP, PROFIBUS FMS and PROFIBUS FDL protocols
  • Universal interface solution for integration in industrial and embedded PCs

Rapid Integration Using API or OPC Server

  • Direct access to all protocols via PROFIBUS API
  • Sample programs including comments
  • Integration in various plant asset management tools
  • Optional access by OPC Clients using Softing‘s OPC Server

Large Choice of Drivers

  • Use in Windows and Linux operating systems
  • PROFIBUS CommDTM for FDT applications included in scope of delivery
Master/Slave, Single Channel 1) Slave, Single Channel 1) Master/Slave, Dual Channel
PROFIBUS Protocol  
DP-V0 Master
DP-V1 Master: Acyclic C2 Services
DP-V2 Master 2)
FMS
FDL
DP-V0 Slave
Fieldbus Connection 9-Pin D-Sub Female, RS485, Galvanically Isolated
Transfer Rates 9.6; 19.2; 45.45; 93.75; 187.5; 500; 1500; 3000; 6000; 12000 Kbit/s
PC Interface PCI V2.2, 128 KB Shared RAM per Channel
Operating Temperature 0oC..+55oC
Storage Temperature -20oC..+70oC
Relative Humidity < 90%, Non-Condensing
Dimensions [mm] 168×64 168×64 168×107
Power Supply
Supply Voltage 5V/3.3V(±5%)DC
Current Consumption [mA] Typ. 500 / 200 Typ. 500 / 200 Typ. 700 / 300
Drivers available for Windows 2000, Windows XP, Windows Vista, Windows 7, Windows 8, Windows 10
Linux
Conformity

1) Also Available with Low Profile Slot Bracket
2) DP-V2 Available for Custom Integration. Please contact Softing to discuss your specific requirements.

PB-PRO 1-PCI (PB-PRO 1-PCI/LP1)) Master/Slave, Single Channel 1)
PB-PRO 1S-PCI (PB-PRO 1S-PCI/LP1)) Slave, Single Channel 1)
PB-PRO 2-PCI Master/Slave, Dual Channel

Scope of Delivery

PC interface Board, CD with Drivers, Documentation and Sample Programs

Additional Products and Services

OPC-PB3) PROFIBUS OPC Server for DP-V0 / DP-V1
DCF-DY-41003) OPC Server for S7 / S5
TRA-PB-TECH PROFIBUS Technology Training

1) Also Available with Low Profile Slot Bracket
3) Requires PROFIBUS Master Interface Board

Training available.. please contact us