mobiLink Power : Single USB interface for PROFIBUS PA, HART, FOUNDATION fieldbus

mobiLink power enables a direct connection to the field device without it having to be located within a functioning bus infrastructure. The integrated power supply eliminates the need for additional components such as external power supply and terminating resistors for commissioning and maintenance of the field devices.

Single interface for the major Process Automation protocols

  • HART Master, Foundation Fieldbus Host and PROFIBUS PA Master included in one device
  • Parametrization and configuration of field devices
  • Diagnostics and condition monitoring

mobiLink Power presentation ( PDF )

Provides the power supply for the field devices

  • Eliminates the need for an additional power supply and power conditioner for workbench applications

Support of FDI, FDT frame applications and major engineering tools

  • PACTware FDT frame application and HART communication DTM included
  • Communication DTM for Foundation Fieldbus and PROFIBUS PA (optional)
  • Foundation Fieldbus configuration tool (optional)
  • Application Program Interface for integration into engineering systems

Unlimited flexibility in use

  • mobilink Power draws power from the connected computer via USB

Please find this product into our renting product

DUA-KM-020440 mobiLink Power for HART applications, including accessories
LRA-KK-021973 linkPlus FF – License to activate Foundation Fieldbus
LRA-LL-021974 linkPlus PA – License to activate PROFIBUS PA
LRA-KK-020721 Licence for FF Configuration Tool ComConf

You may also be interested in :

mbGate PB

MODBUS TCP SERVER to PROFIBUS PA/DP Master Gateway

imple connection of PROFIBUS Slave Devices to Modbus Control Systems via Internal I/O Mapping

With mbGate PB it is possible to integrate up to 2 PROFIBUS PA segments and 1 PROFIBUS DP segment into Modbus TCP control systems. It acts as Modbus TCP Server and PROFIBUS Master. With our gateway the engineering costs can be reduced since it re-uses existing power conditioners in technology upgrade projects. It enables configuration, parameterization and plant asset management using standard industry tools.

Similar solutions:
mbGate PA: Modbus TCP to PROFIBUS PA Gateway – Integrate PROFIBUS PA segments into Modbus Control system
mbGate DP: Modbus TCP to PROFIBUS DP Gateway – Integrate PROFIBUS DP segments into Modbus Control system

Key Component for Transition to State-of-the-Art Technology

  • Simple replacement of installed PROFIBUS DP/PA segment couplers
  • Re-use of existing PROFIBUS segments without requiring modification

Direct Connectivity to PROFIBUS Segments

  • Single access point to PROFIBUS DP and PROFIBUS PA segments from Modbus TCP networks
  • Acting as Modbus TCP Server and PROFIBUS PA and PROFIBUS DP Master
  • Support of one PROFIBUS DP segment and up to two PROFIBUS PA segments

Configuration, Parameterization and Plant Asset Management Using Standard Industry Tools

  • Supports major Modbus engineering tools such as Schneider Unity Pro or Siemens TIA Portal
  • Included CommDTM allowing use in FDT/DTM frame applications
  • EDD-based device parametrization using Siemens Simatic PDM

MODBUS/TCP Redundancy

  • Supports the use of two redundant PLCs and two redundant gateways
  • Easily enabled via licensing
  • Full control of redundant operation mode via engineering and PLC
Scope of Delivery
Hardware mbGate PB Gateway
Documentation On Website
Order Numbers
GCA-EN-024808 mbGate PB, Modbus TCP to PROFIBUS Gateway. Supports 2 PA segments (up to 32 PA devices, MBP physical layer) and 1 PROFIBUS DP segment (RS485).
Additional Products and Services
LRA-EN-024851 gatePlus HighAvailability, License for activating redundancy features in mbGate PB
LRL-DY-134501 dataFEED OPC Suite, Version 4.01 and higher, including all supported PLC protocols, support for OPC UA, access for any number of dataFEED OPC Tunnel Clients, for simultaneous access to a total of up to 100 OPC UA Servers, OPC Servers and OPC Tunnel Servers, and many more Functionalities such as Database and File Access, Data Exchange, Optimizer, Concentrator and Bridge
GCA-EL-024802 mbGate PA, Modbus TCP to PROFIBUS PA Gateway. Supports up to 2 PA segments (up to 32 PA devices).
GCA-EL-024804 mbGate PA, Modbus TCP to PROFIBUS PA Gateway. Supports up to 4 PA segments (up to 64 PA devices).
GCA-EN-024806 mbGate DP, Modbus TCP to PROFIBUS DP Gateway. Supports 1 PROFIBUS DP segment (RS485).
Fieldbus Infrastructure
Installation solutions When using the high-power trunk topology or FISCO, we offer in cooperation with R.Stahl, fieldbus infrastructure components with PROFIBUS PA and FOUNDATION fieldbus H1 – this ranges from power supply, physical layer diagnostics and field device couplers to termination resistors.

mbGate PA

MODBUS TCP SERVER to PROFIBUS PA Master Gateway

Simple connection of PROFIBUS PA Slave devices to Modbus control systems via internal I/O mapping

With mbGate PA it is possible to integrate up to 4 PROFIBUS PA segments into Modbus TCP control systems. It acts as Modbus TCP Server and PROFIBUS PA Master. With our gateways the engineering costs can be reduced since it re-uses existing power conditioners in technology upgrade projects. It enables configuration, parameterization and plant asset management using standard industry tools.

Similar solutions:
mbGate PB: Modbus TCP to PROFIBUS PA/DP Gateway –  Integrate PROFIBUS DP/PA segments into Modbus Control Systems
mbGate DP: Modbus TCP to PROFIBUS DP Gateway – Integrate PROFIBUS DP segments into Modbus Control system

 

Key Component for Transition to State-of-the-Art Technology

  • Simple replacement of installed PROFIBUS DP/PA segment couplers
  • Re-use of existing PROFIBUS PA segments without requiring modification

Direct Connectivity to PROFIBUS Segments

  • Acting as Modbus Server and PROFIBUS PA Master
  • Connects up to 4 PROFIBUS PA Segments to Modbus TCP

Configuration, Parameterization and Plant Asset Management Using Standard Industry Tools

  • Supports major Modbus engineering tools such as Schneider Unity Pro or Siemens TIA Portal
  • Included CommDTM allowing use in FDT/DTM frame applications
  • EDD-based device parametrization using Siemens Simatic PDM

Scope of Delivery
Hardware mbGate PA Gateway
Documentation On Website
Order Numbers
GCA-EL-024802 mbGate PA, Modbus TCP to PROFIBUS PA Gateway. Supports up to 2 PA segments (up to 32 PA devices).
GCA-EL-024804 mbGate PA, Modbus TCP to PROFIBUS PA Gateway. Supports up to 4 PA segments (up to 64 PA devices).
Additional Products and Services
LRL-DY-134501 dataFEED OPC Suite, Version 4.01 and higher, including all supported PLC protocols, support for OPC UA, access for any number of dataFEED OPC Tunnel Clients, for simultaneous access to a total of up to 100 OPC UA Servers, OPC Servers and OPC Tunnel Servers, and many more Functionalities such as Database and File Access, Data Exchange, Optimizer, Concentrator and Bridge
GCA-EN-024806 mbGate DP, Modbus TCP to PROFIBUS DP-Gateway. Support of 1 PROFIBUS DP segment (RS485).
GCA-EN-024808 mbGate PB, Modbus TCP to PROFIBUS Gateway. Supports 2 PA segments (up to 32 PA devices, MBP physical layer) and 1 PROFIBUS DP segment (RS485).

Power Conditionner – 9412/00-310-11S

9412 Series – Power Conditionner

Single or redundant 9412 series fieldbus power supplies are used to supply an FF H1 High Power Trunk with up to 28 V/500 mA, and up to 1 A in Boost mode. In the background, they measure the advanced physical layer parameters, which can be reported via an Android smartphone, configurable integrated alarms or online via FF H1. 9419 series bus carriers or DIN rails can be used for installation.

  • For single or redundant power supply to FOUNDATION Fieldbus H1 segments (High Power Trunk)
  • Output > 28 V, up to 1 A, galvanically separated
  • Integrated advanced physical layer diagnostics

General

WebCode 9412A
Product Variant Fieldbus Power Supply
Product Type 9412/00-310-11s
Product Description ISbus fieldbus technology Fieldbus power supply
Highlights For single or redundant power supply to FOUNDATION Fieldbus H1 segments (High Power Trunk)
Output > 28 V, up to 1 A, galvanically separated
Integrated advanced physical layer diagnostics
Functional Description Single or redundant 9412 series fieldbus power supplies are used to supply an FF H1 High Power Trunk with up to 28 V/500 mA, and up to 1 A in Boost mode. In the background, they measure the advanced physical layer parameters, which can be reported via an Android smartphone, configurable integrated alarms or online via FF H1. 9419 series bus carriers or DIN rails can be used for installation.
Description fieldbus power supply and diagnostics
Application range (zones) 2, 22
IECEX gas certificate IECEx BVS 09.0043X
ATEX gas certificate BVS 09 ATEX E 099 X
Certificate EAC TS RU S-DE.GB04.B.00081
Gas explosion protection IECEx Ex nA nC IIC T4 Gc
Gas explosion protection ATEX II 3 G Ex nA nC IIC T4 Gc
Gas explosion protection EAC 2 Ex nA nC IIC T4 Gc X
Certificates ATEX (BVS), Brazil (ULB), Canada (FM), EAC (STV), IECEx (BVS), India (PESO), International (FF), USA (FM)
Number of channels 1
Supply voltage DC 24.00 V
Segment supply Ua ≥ 28 V DC
Segment supply Ua note Other voltage variant for ic-FISCO and entity on request
Nominal voltage 24 V DC
Max. power dissipation 2.75 W
Max. power dissipation note at 500 mA output current and 24 V auxiliary power
Segment supply Ia 500.00 mA
Segment supply Ia note Up to 1 A in boost mode
Error message Overload and short circuit
Error messaging device Relay contact (30 V DC/100 mA)
Fieldbus Specification IEC 61158-2, FOUNDATIONTM fieldbus H1 FF-831
Ambient temperature min. -20 °C
Ambient temperature max. +70 °C
Ambient temperature -20 °C … +70 °C

pnGate PA

PROFINET to PROFIBUS PA Gateway (pnGate PA)

Direct PROFIBUS PA Segment Integration into PROFINET Control Systems

  • Re-use of Existing Power Conditioners in Technology Upgrade Projects
  • No PROFIBUS DP Intermediate Segment required
  • Prepared for Integration in Standard Engineering and Plant Asset Management Tools

Key Component for Transition to State-of-the-Art Technology

  • Simple replacement of installed PROFIBUS DP/PA segment couplers
  • Re-use of existing PROFIBUS PA segments without requiring modification
  • Support of PROFINET redundancy for increased reliability

Direct Connectivity to PROFIBUS Segments

  • Acting as PROFINET Device and PROFIBUS PA Master
  • Support of up to 4 PROFIBUS PA segments

Configuration, Parameterization and Plant Asset Management Using Standard Industry Tools

  • Supports major PROFINET engineering tools such as TIA Portal, Step7 and PC WORXS
  • Included CommDTM allowing use in FDT/DTM frame applications
  • EDD-based device parametrization using Siemens Simatic PDM
Technical Details
Hardware Processor
Status LEDs (Gateway)Status LEDs (Fieldbus)
Altera Cyclone V SoC with dual-core ARM Cortex-A9
PWR (power supply), RUN (operation), ERR (error), CFG (configuration and update)
SF (system fault), BF (bus fault)
Interfaces and Connectors Ethernet

PROFIBUS PA

2 * IEEE 802.3 100BASE-TX / 10BASE-T, embedded PROFINET switch for daisy chain topology
Connectors: RJ45
Protocol: PROFINET RT / IRT, Support of PROFINET redundancy protocols
RESTful API interface for device configuration
Up to 4 PROFIBUS PA (MBP) segments (refer to the section “Order Numbers”),
Bus-powered Medium Attachment Unit (MAU): Fieldbus voltage range: 9 VDC … 32 VDC,
current consumption 10 mA,
Connectors: 3-position screw connection, galvanically isolated
Physical Properties Dimensions (H x W x D)
Weight
Power SupplyOperating / Storage Temperature
Relative Humidity
Cooling
Coating
Mounting
Protection Class
100 mm x 35 mm x 105 mm
About 0.25 kg
18 VDC … 32 VDC; SELV/PELV power supply mandatory
Typical input current: 200 mA, maximum input current: 1 A (allowing for in-rush current at switch-on)
No power supply to PROFIBUS PA segments through pnGate PA
-40 °C … +70 °C / -40 °C … +85 °C
(see detailed mounting description in user manual)
10 % … 95 %, non-condensing
Convection, no fan
Conformal coating based on ANSI / ISA-S71.04 G3
DIN rail 35 mm
IP20
Scope of Delivery
Hardware pnGate PA Gateway
Software GSDtoGSDML Converter, FDT CommDTM, PACTware, Drivers and Tools
Documentation On CD-ROM
Order Numbers
GCA-AL-024602 pnGate PA, PROFINET to PROFIBUS-PA Gateway. Supports up to 2 PROFIBUS PAsegments (up to 32 PA devices).
GCA-AL-024604 pnGate PA, PROFINET to PROFIBUS-PA Gateway. Supports up to 4 PROFIBUS PAsegments (up to 64 PA devices).
GCA-AL-024605 pnGate PA (for STAHL carrier), PROFINET to PROFIBUS-PA Gateway. Supports up to 4 PROFIBUS PA segments (up to 64 PA devices). For reversed mounting position on STAHL backplane.
Additional Products and Services
GCA-AN-024608 pnGate PB, PROFINET to PROFIBUS Gateway. Supports up to 2 PROFIBUS PAsegments (up to 32 PA devices, MBP physical layer) and 1 PROFIBUS DP segment (RS485).
GCA-EL-024802 mbGate PA, Modbus/TCP to PROFIBUS-PA Gateway. Supports up to 2 PROFIBUS PA segments (up to 32 PA devices).
GCA-EL-024804 mbGate PA, Modbus/TCP to PROFIBUS-PA Gateway. Supports up to 4 PROFIBUS PA segments (up to 64 PA devices).

pnGATE PB

PROFINET to PROFIBUS DP/PA Gateway (pnGate PB )

With the pnGate : Direct Integration of PROFIBUS DP and PA Segments into PROFINET Control Systems

  • Re-use of Existing Power Conditioners in Technology Upgrade Projects
  • No PROFIBUS DP Intermediate Segment required
  • Prepared for Integration in Standard Engineering and Plant Asset Management Tools
csm_pnGate_PB_application_EN_1000px_rgb_4fdcab893e

Key Component for Transition to State-of-the-Art Technology with the pnGATE PB from Softing

  • Simple replacement of installed PROFIBUS DP/PA segment coupler
  • Re-use of existing PROFIBUS segments without requiring modification
  • Support of PROFINET redundancy for increased reliability

Direct Connectivity to PROFIBUS Segments

  • Single access point to PROFIBUS DP and PROFIBUS PA segments from PROFINET networks
  • Acting as PROFINET Device, PROFIBUS PA and PROFIBUS DP Master
  • Support of one PROFIBUS DP segment and up to two PROFIBUS PA segments

The pnGate PB, allows you configuration, parameterization and plant Asset Management using standard industry tools

  • Supports major PROFINET engineering tools such as TIA Portal, Step7 and PC WORXS
  • Included CommDTM allowing use in FDT/DTM frame applications
  • EDD-based device parametrization using Siemens Simatic PDM
Technical Details
Hardware Processor
Status LEDs (Gateway)Status LEDs (Fieldbus)
Altera Cyclone V SoC with dual-core ARM Cortex-A9
PWR (power supply), RUN (operation), ERR (error), CFG (configuration and update)
SF (system fault), BF (bus fault)
Interfaces and Connectors Ethernet

PROFIBUS PA

PROFIBUS DP-V0 / V1

2 * IEEE 802.3 100BASE-TX / 10BASE-T, embedded PROFINET switch for daisy chain topology
Connectors: RJ45
Protocol: PROFINET RT / IRT, Support of PROFINET redundancy protocols
RESTful API interface for device configuration
2 * PROFIBUS PA (MBP) segments,
Bus-powered Medium Attachment Unit (MAU): Fieldbus voltage range: 9 VDC … 32 VDC,
current consumption 10 mA,
Connectors: 3-position screw connection, galvanically isolated
1 Segment with RS485 Physical Layer, Connector: 9-pin Sub-D socket
Physical Properties Dimensions (H x W x D)
Weight
Power SupplyOperating / Storage Temperature
Relative Humidity
Cooling
Coating
Mounting
Protection Class
100 mm x 35 mm x 115 mm
Approx. 0.25 kg
18 VDC … 32 VDC; SELV/PELV power supply mandatory
Typical input current: 200 mA, maximum input current: 1 A (allowing for in-rush current at switch-on)
No power supply to PROFIBUS PA segments through pnGate PB
-40 °C … +70 °C / -40 °C … +85 °C
(see detailed mounting description in user manual)
10 % … 95 %, non-condensing
Convection, no fan
Conformal coating based on ANSI / ISA-S71.04 G3
DIN rail 35 mm
IP20
Scope of Delivery
Hardware pnGate PB Gateway
Software GSDtoGSDML Converter, FDT CommDTM, PACTware, Drivers and Tools
Documentation On CD-ROM
Order Numbers
GCA-AN-024608 pnGate PB, PROFINET to PROFIBUS Gateway. Supports up to 2 PROFIBUS PA segments (up to 32 PA devices, MBP physical layer) and 1 PROFIBUS DP segment (RS485).
Additional Products and Services
GCA-AL-024602 pnGate PA, PROFINET to PROFIBUS-PA Gateway. Supports up to 2 PROFIBUS PA segments (up to 32 PROFIBUS PA devices).
GCA-AL-024604 pnGate PA, PROFINET to PROFIBUS-PA Gateway. Supports up to 4 PROFIBUS PA segments (up to 64 PROFIBUS PA devices).
GCA-AL-024605 pnGate PA (for STAHL carrier), PROFINET to PROFIBUS-PA Gateway. Supports up to 4 PROFIBUS PA segments (up to 64 PROFIBUS PA devices). For reversed mounting position on STAHL backplane
GCA-EL-024802 mbGate PA, Modbus/TCP to PROFIBUS-PA Gateway. Supports up to 2 PROFIBUS PA segments (up to 32 PROFIBUS PA devices).
GCA-EL-024804 mbGate PA, Modbus/TCP to PROFIBUS-PA Gateway. Supports up to 4 PROFIBUS PA segments (up to 64 PROFIBUS PA devices).

( coming soon )

pnGate PA/PB Configuration in TIA Portal

Easy Parameterization of PROFIBUS PA Devices in SIMATIC PDM with pnGate PA

mobiLink Interface

Mobile Interface for HART, FOUNDATION fieldbus, Profibus PA

csm_mobiLink_5ff21a0363

mobiLink is a both Bluetooth and USB solution for commissioning parameterization & maintenance for field devices

  • Single interface for the major Process Automation protocols: HART / Foundation fieldbus / PROFIBUS PA
  • Perfectly suited for handheld host devices due to battery powered Bluetooth operation
  • Compatible with FDT Frame Applications
  • Approved for use in hazardous areas

Multi protocol operation available on mobiLink

  • HART Master, Foundation fieldbus Host and PROFIBUS PA Master  included in one device
  • Temporary attachment to fieldbus segments or HART loops for individual interaction with field devices
  • Fully compliant protocol implementations allow for interference-free access to running plants

Host communication via Bluetooth or USB

  • Built-in batteries and Bluetooth communication enable use of handheld host devices like smart phones and tablets
  • USB interface for bench host operation

mobiLink support of FDT Frame Applications and major Engineering Tools

  • PACTware FDT Frame Application and HART Communication DTM included
  • Communication DTM for Foundation fieldbus and PROFIBUS PA (optional)
  • Foundation fieldbus configuration tool (optional)
  • Application Program Interface for integration into Engineering Systems

Suitable for use in hazardous areas

  • The mobiLink is EX approval for Zone 1
  • Suitable for connection to intrinsically safe circuits
  • Suited for harsh environment
User Interface Controls
Status LEDs
Power on/off button, Bluetooth pairing button
FIELDBUS (Fieldbus mode), HART (HART mode), Bluetooth (Pairing/Bluetooth active), Low battery, Power on
Interfaces and Connectors USB

Bluetooth

Fieldbus

HART

Speed: USB 2.0 Full Speed
Connector: USB Type C
Electrical: Non intrinsically safe. Do not use inside hazardous areas.
5V, 100mA. Um = 253VBT mode: BT Classic, 2.4 – 2.478 GHz Output Power: +8 dBm (maximum)Connection: 4 mm banana type jacks (red/black), polarity has to be observed
Physical Layer: according to IEC 61158-2, Type 1: 31.25 Kbit/s, voltage mode
Nominal input current (Fieldbus):
10 mA in Bluetooth and regular USB mode
18 mA (with Ufieldbus > 9,5V) for increased battery life time in USB mode (controlled by application)
Fieldbus Terminator: No fieldbus terminator includedConnection: 4 mm banana type jacks (red/black)
Physical Layer: HART FSK compliant modem
Operation in Hazardous Areas Intrinsic Safety Parameters EX ia IIB, Ui = 30 V or FISCO field device
Isolation: 1500 VDC between USB and Fieldbus, 1500 VDC between USB and HART
Physical Properties Dimensions (L x W x D)

Weight

Power Supply

Operating Temperature

Storage

Relative Humidity

Protection Class

175 mm x 74 mm x 32 mm

330 g (incl. Batteries)

Battery: 3 * Alkaline, IEC-LR6, nominal voltage 1,5V
For use in hazardous area: Energizer E91 or Duracell Procell MN1500.
With batteries of other types or manufacturers certification is void.
Fieldbus interface (Medium Attachment Unit) powered by fieldbus.

-20°C .. +50°C

Store batteries in a dry place at normal room temperature.

< 95% rH non condensing

IP 54 (if USB port covered with cap)

Scope of Delivery
Hardware mobiLink, USB cable, fieldbus cable set with clips, 3 * Alkaline IEC-LRC6, USB memory stick
Software PACTware, Communication DTM for HART, Foundation Fieldbus and PROFIBUS PA (for Foundation Fieldbus and PROFIBUS PA optional license required)
Foundation Fieldbus Configuration Tool ComConf (optional license required)
Documentation On USB memory stick
Order Numbers
DBA-KM-020410 mobiLink for HART applications
LRA-KK-021971 Licence for FF CommDTM
LRA-NN-021972 Licence for PA CommDTM
LRA-KK-020721 Licence for FF Configuration Tool ComConf
DBL-KM-020411 mobiLink HART incl. FF Comm DTM Licence
DBL-KM-020412 mobiLink HART incl. FF and PA Comm DTM Licenc

How to connect with Foundation Fieldbus devices via mobiLink:

How to connect with Foundation Fieldbus devices via mobiLink:

How to change Foundation Fieldbus node addresses:

People interested in this product, are also interested in :

BC-230-PB

Profibus PA Tester ( BC-230-PB) for ATEX and non ATEX Zones

Profibus PA tester

ATEX zone Certified

Atex

The PROFIBUS PA Tester is a versatile tool for testing PROFIBUS PA Network .

Quick and Easy Bus Testing

The Diagnostic Monitor ( BC-230-PB)  is a versatile tool for testing PROFIBUS PA networks during operation. It is powered by the fieldbus, so that no battery or external power source is required. The monitor is also suitable for use in hazardous areas ( ATEX product)

Universal Application of the BC-230-PB

  • Testing of the bus physics
  • Verification of stable communication between the bus devices
  • Universal tool for setup and commissioning, documentation, acceptance testing, predictive maintenance, and troubleshooting

BC-230-PB is very simple to use

  • Outstanding ease of use based on display and two function buttons ▪ Clear classification of test results as either OK or BAD
  • Ideal choice even for less experienced users

Fully Automatic Bus Test

  • Automatically powered by fieldbus and start of segment testing without operator intervention after attachment to PROFIBUS PA network
  • Information in plain text, if measured data exceeds tolerance limits
  • Measurement of segment voltage as well as average noise and peak noise for three frequency ranges
  • Reliable detection of short circuits between individual signal wires and cable shield
  • Detection of all frame retransmissions and all devices added or dropped during bus operation at field device level
  • Determination of current and lowest signal levels of all devices
  • No PC or notebook needed for testing the bus
  • Internal storage of test data for later transfer to PC
  • Detailed test reports in Microsoft Excel or text format
put voltage: Fieldbus mode: 8 to 32 VDC, USB mode: 4.1 to 5.5 VDC
Max. input current: Fieldbus mode: 10 mA *, USB mode: 30 mA
Power dissipation: Fieldbus mode: max. 320 mW (at 32 VDC), USB mode: max. 165 mW (at 5.5 VDC)
Operating temperature: –20 to +50 °C **
Dimensions: 146 x 88 x 28 mm
Weight: 378 g
Case material: ABS
DC voltage measurement range: 8 to 32 VDC ± 0.5 VDC
Signal level measurement range: 0.12 to 2 Vpp ±10% ±0.025 Vpp
LF noise measurement range: 50 Hz to 4 kHz, 0 to 1000 mVpp ±15% ±25 mVpp ***
FF noise measurement range: 9 kHz to 40 kHz, 0 to 1000 mVpp ±10% ±25 mVpp ***
HF noise measurement range: 90 kHz to 350 kHz, 0 to 250 mVpp ±20% ±25 mVpp ***
Conformity CE, FCC
Hazardous area approvals FM USA and Canada:
—Class I Division 2 Groups A, B, C and D T4
—Class I Zone 2 Group IIC T4
—Class I Division 1 Groups A, B, C and D T4
—Class I Zone 0 and 1 Ex/AEx ia IIC T4
ATEX Ex ia IIC T4
ATEX Ex nL IIC T4
ATEX Ex ic IIC T4
Data transfer to PC Via supplied PC software for Windows 2000, XP and VISTA, Windows 7 (32/64 bit) and USB interface version 1.1 or 2.0
*  In  fieldbus  mode  the BC-230-PB  is powered by the  fieldbus and draws approximately 9.4 mA of current from the segment (depending on bus voltage and ambient temperature).
**  Display update speed is impaired below –10°C.
*** Vpp = Volts peak-to-peak; excessive noise adjacent to the fieldbus frequency (FF) band will prevent the BC-230-PB from reading the fieldbus data and thus reduce functionality.
BC-230-PB Diagnostic Monitor for PROFIBUS PA

Scope of Delivery

Hardware Diagnostic Monitor for PROFIBUS PA (BC-230-PB), connection cables, carrying case
Software PC software (in English) on CD-ROM
Documentation Manual (in English), certificates (in English)

Additional Products and Services

PB-LSZ-CHB3 Digital fieldbus leakage current clamp for locating EMC problems, 40 Hz … 1,000 Hz, Min/Max, Data Hold, measuring cables, supplied in handy case

Training available on demand

This product belongs to our Process Automation family. In order to view our expertise and the complete list of products please Download the Process Automation Brochure.

PROFIBUS Tester 5 (BC-700-PB)

BC-700-PB : Quick and easy test : Physics bus, communication bus and cable testing

The PROFIBUS Tester 5 (BC-700-PB) is a powerful diagnostic and troubleshooting tool for testing the cables, measuring the signals and analyzing the communication of PROFIBUS networks. It is battery-powered and provides a graphical display, allowing for quick results when working in stand-alone mode. Optionally, also PROFIBUS PA network can be analyzed. In addition, the BC-700-PB supports the export of test results for advanced analysis.

BC-700-PB

Test Bus Câblage, Physique Bus et Bus Communication “All-In-One”

  • Combinaison de testeur de signal, oscilloscope à mémoire, protocolanalyzer, simulateur de maître et la fonctionnalité de testeur de câble en un seul outil de diagnostic
  • Mode autonome, plus des diagnostics basés sur PC étendues
  • Adaptés pour l’installation, la configuration et la mise en service, la documentation, les tests d’acceptation, l’optimisation du réseau, la maintenance préventive, le dépannage ainsi que des tests de laboratoire

Très mobile Bus Testeur pour l’essai Même Sans Notebook

  • fonctionnement sur batterie sans avoir besoin d’alimentation supplémentaire
  • Affichage graphique fournissant facile à comprendre la présentation des résultats des tests
  • tests de réseau complets en mode autonome sans nécessiter un ordinateur portable

Caractéristiques de diagnostic améliorée grâce à complément logiciel PC-Based

  • De nombreuses fonctionnalités supplémentaires pour l’exécution, l’analyse et la gestion des tests de bus en mode PC (Tendance, Topologie Numériser, Master Simulator, Oscilloscope, analyseur Frame)
  • Test rapide et test contrôlé par l’utilisateur pour l’évaluation de l’état du réseau facile à la simple pression d’un bouton
  • Génération de rapports d’essais qui décrivent l’état actuel de l’installation PROFIBUS
  • Idéal pour les utilisateurs moins expérimentés, ainsi que pour les spécialistes de bus de terrain

Adaptateur de mesure en option pour MBP (Manchester Coded Bus Powered) Physique

  • Analyse spécifique du signal de support physique MBP (de feedingvoltage, type de signal, le signal de polarité, divergence bitrate)
  • Analyse complète du protocole directement au niveau du segment PROFIBUS PA
Diagnostics Functionality
Protocol and Frame Analysis PROFIBUS DP-V0 and DP-V1, automatic baud rate detection in the range of 9.6 kbit/s … 12 Mbit/s
Signal Analysis PROFIBUS DP-V0, DP-V1, FMS and MPI
… via EIA-485 Signal quality index 0 … 5,000, determined from signal wave form as well as signal/noise ratio and rise time; signal sampling with 8/16 samples per bit
… via MBP
(requires optional adapter)
Fieldbus feeding voltage: 0 V … 35 V at 0.1 V resolution, signal level: 100 mV … 1,200 mV at 10 mV resolution, signal polarity, bitrate divergence: ±1.2 % at 0.01 % resolution, signal sampling with 128 samples per bit
Oscilloscope Display
(Not Available for MBP)
Test range: ±5 V at 10 mV resolution (differential), 0 V … 15 V at 15 mV resolution (A or B to DGND);
sampling rate: up to 384 Msamples/s; sampled points: 2,400 (signal details), 8,192 (oscilloscope analysis)
Topology Scan
(Not Available for MBP)
Active, maximum distance: 230 m, accuracy: ±2 m
Cable Test
(Not Available for MBP)
Active, supported cable segment length: 5 m … 1,500 m, accuracy: 5 %
Operation Via graphical colour display, four function keys and scrollwheel including central push-button or via PC/notebook
Internal Memory Capacity 3 user-definable network directories (segment and test location) for storing quick tests, trend logs and cable test results
Trend logging: max. 99 hours
Trigger IN: L = 0 V .. 0.8 V; H = 2.4 V .. 24 V; pulse > 10 μs, active high
OUT: approximately 5 V, active low (connection to storage oscilloscope)
PC Operating Software PROFIBUS Diagnostics Suite, see separate datasheet for details
Connectors
EIA-485 (PROFIBUS DP) PROFIBUS D-sub connector, 9 pins, power supply for external bus termination
MBP (PROFIBUS PA) Connector, 3 pins, for screw terminals at optinal measuring adapter, measuring cable set including 3 probes(adapter for MBP measurement is attached to D-sub connector)
USB V 2.0, high speed 480 Mbit/s, galvanically isolated
Dimensions (H x W x D) 35 mm x 220 mm x 110 mm
Power Supply Built-in three-cell lithium-ion battery supporting 11.1 VDC or external AC adapter 100 VAC … 240 VAC, 50/60Hz (galvanically isolated)
The rechargeable battery has a runtime of up to 5 hours (runtime depends on the performed test functionality and rate of wear of the rechargeable battery)
Battery is charged via external AC adapter
Operating/Storage Temperature Operating temperature: 0 °C … 50 °C, storage temperature: -20 °C … 70 °C
Relative Humidity Air humidity: 10 % … 90 % without condensation
Weight Test tool, no cable: approximately 0.75 kg; complete carrying case: approximately 4.2 kg
Conformity CE, FCC, VCCI
ATV-DDA-NN-006014 PROFIBUS Tester 5 (BC-700-PB)
ATV-DDL-NN-006012 PROFIBUS Tester 5 (BC-700-PB) with Oscilloscope Option
ATV-LRA-NN-006011 Oscilloscope Option (Oscilloscope view in stand-alone mode)
ATV-DDL-NL-006010 PROFIBUS PA option for BC-700-PB (BC-700-PB serial number required for order placement)

Scope of Delivery

Hardware PROFIBUS Tester 5 (BC-700-PB), power supply unit 100 VAC … 240 VAC, 50/60 Hz with connecting cables for Europe and USA, adaptor cables, carrying case
Measuring adapter BC-700-H1, measuring cable set (for PROFIBUS PA option)
Software PROFIBUS Diagnostics Suite (PC software for Windows on CD-ROM)
BC-700-PB upgrade license (on CD-ROM, for PROFIBUS PA option)
Documentation Device Manual, “Getting Started“ Manual

Additional Products and Services

ATV-ACA-NN-006031 EIA-485 D-Sub adapter cable for testing operational networks with reduced influence on segment operation
ATV-ACA-NN-006033
(view product)
D-Sub to M12 adapter set with T-piece and M12 bus termination for PROFIBUS DP
ATV-PB-LSZ-CHB3
(view product)
Digital Fieldbus Leakage Current Clamp for Locating EMC Problems, 40 ..1000 Hz, MIN/MAX, Data Hold, Measuring Cables, supplied in a Handy Case (fits in Empty Compartment of Carrying Case)
ATV-BC-PBMB-PB-S
(view product)
D-Sub Service Interface with Active Bus Termination and 90° Angled Connector for PROFIBUS DP
ATV-BC-M12DP-PB
(view product)
M12 Service Interface for PROFIBUS DP, Comprising M12 T-Piece, End Cap and M12 Connection Cable (1 m)

PROFIBUS Diagnostics Suite

Universal Software for All Diagnostic Tools of the bus check Family

PC software for performing, evaluating and managing tests of bus physics, bus communication and cabling in PROFIBUS networks. The application is extremely easy to use, with a quick test available at a click of the mouse.

 

One Software for All Diagnostic Products

  • Comprehensive analysis of PROFIBUS DP and PROFIBUS PA networks
  • Diagnostic functionality available depending on connected test tool
  • License-free use on any number of PCs – no activation required

Suitable for the Fieldbus Novice

  • Bus test initiated with a single mouse click
  • Clear, easy-to-read display of test results
  • Separate expert mode providing in-depth diagnostic features for network specialists

Functionality for All Diagnostic Tasks

  • Continuous display of current bus status in status bar
  • Overall bus health indicated by traffic light symbols for bus physics and bus communication
  • Detail views with additional diagnostic information, also for advanced analyses by experts
  • Testing of bus and connected devices via integrated master simulator without configuration or parameterization
  • Generation of test reports for acceptance testing of PROFIBUS installations

Technical Data

Operating Systems:
PC Hardware*
RAM 500 MB for Windows XP
1 GB for Windows 7, Windows 8
Processor 1 GHz for recording at baud rates up to 1.5 Mbit/s
2 GHz for recording at baud rates over 1.5 Mbit/s
Screen Resolution 1024 x 768 pixels (XGA)
USB Interface 2.0
Supported Operating Systems Windows XP, Windows 7, Windows 8

* The above minimum requirements are only general guidelines. Requirements may vary depending on the PC/notebook used.

PROFIBUS Tester : OPTIONS

 

M12 Cable and connectors 

People interested in this product, may be interested in :