TH Link PROFIBUS

TH Link PROFIBUS

Plant Asset Management with optional monitoring for PROFIBUS Networks

Access to PROFIBUS networks for any FDT frame application, Emerson’s AMS and Softing’s TH SCOPE

THLINK PROFIBUS provides controller-independent access to PROFIBUS networks for plant operation and maintenance staff. The tool supports both plant asset management applications and network diagnostics. THLINK PROFIBUS is easy to be integrated without interfering withthe operation of existing installations.

Independent Access to PROFIBUS Network

  • Controller-independent
  • Independent of configuration tools
  • Access for plant asset management applications to configure field devices based on FDT/DTM and EDDL standards (acyclic master)

Designed for Installation without Interference with Plant Operation

  • Connection to PROFIBUS network also possible during operation of the plant
  • Easy integration into existing plants thanks to compact design
  • Browser access for administration and configuration purposes

Powerful Data Collection Capabilities Optimized for PROFIBUS

  • Passive listening to PROFIBUS DP protocol
  • Threshold monitoring for frame retries
  • Statistics for optimization of the network configuration
  • Easy detection of missing terminating resistors

Optimized for Use by Maintenance Engineers

  • Central and time-saving parameterization of PROFIBUS and HART field devices directly from the control room
  • Continuous monitoring and troubleshooting for PROFIBUS networks
  • Fault identification with intelligent troubleshooting assistance
  • Seamless integration with TH SCOPE diagnostics software
Functionality
  • Network detection and data collection (PROFIBUS DP)
  • Acyclic master (PROFIBUS DP-V1)
  • Alarm notification in case of fault
  • Basic monitoring, configuration
  • Integrated web server
Supported Plant Asset Management Applications e.g.:

  • Endress+Hauser FieldCare
  • Emerson AMS Suite
  • Yokogawa Fieldmate
  • PACTware
PROFIBUS Transmission Rate
  • max. 12 MBit/s (AMS Device Manager, FDT)
  • max. 1.5 MBit/s (TH SCOPE)
Input Voltage 24 VDC (19.2 VDC … 28.8 VDC)
Current consumption max. 190 mA
Operating Temperature 0 °C … 50 °C
PROFIBUS interface RS 485
Ethernet Port RJ-45 (10Base-T/100Base-TX)
Mounting 35 mm DIN rail
Dimensions (H x W x D) 22.5 x 99 x 114.5 mm
Weight 120 g
Certificate CE
  • ATV-GEA-JN-003006 TH LINK PROFIBUS

    Scope of Delivery

    Hardware TH LINK PROFIBUS
    Documentation Installation Manual, Release Notes (by download)

    Additional Products and Services

    ATV-LRA-JY-003024 TH SCOPE (software key)
    ATV-LRL-JY-003025 TH SCOPE (hardware key)
    ATV-LRA-NN-021980 DTM Library
    ATV-VAA-YY-023000 PACTware
    ATV-VAA-NM-023001 TACC