NetXpertXG

Test your Ethernet cable. Prove the speed limit.

ATEVA Technologie : NetXpert

Wireless access point speeds at the end of the network are out-pacing the speeds of the installed cabling in the middle of the network. Is it possible that your installed cabling will handle speeds beyond design spec and will keep up with speeds of the new wireless access points? Is it possible to leave your CAT 5e and CAT 6 cables in place, and achieve 1Gbit/sec speeds?  10Gbits/sec speeds?

To find out, with the single press of a button, three key tests are run with the NetXpert XG. In one click, NetXpert XG performs a live speed test sending 1Gb/s through your cable (BERT), and will prove if the cable will perform beyond design spec and keep pace with the speed of newly installed access points.

NetXpert XG is the only cable tester and active network manager to perform BERT (bit error rate test), SNR (signal-to-noise ratio), and delay skew to 1G, 5G, or 10G speeds at the press of a button. Now you can perform real-time bit throughput tests to see if your installed cables will run up to 10Gb.

 

One touch bit error rate test, signal-to-noise ratio, and delay skew

By performing a Bit Error Rate Test (BERT) and standards based tests as per IEEE 802.3an, the NetXpert XG proves the error-free data transmission up to 10Gb/s.

A one touch auto test includes BERT, signal-to-noise ratio (SNR), and delay skew, all of which can impact Gigabit transmission.

Signal-to-noise ratio checks to ensure noise is low enough and signal is high enough for reliable transmission.  Delay skew indicates the signal time delay between the wire pairs. Excessive delay from one pair can result in a serious degradation of transmission performance making it impossible for the receiver to interpret the data stream correctly.

All three crucial measurements for determining reliable data transmission are performed at the touch of a button.  When you are ready to test the next cable, hit test again, and NetXpert XG advances automatically to the next cable being tested.  Each test result is automatically stored to a summary report and a detailed report in pdf, csv, or xml format.

The cable qualifier that is defining a new category — the cable project qualifier

If you are a cable installer, network owner, network builder, or system integrator, you’ll be excited to hear that NetXpert XG includes a project editor and auto test generator for up to 1000 cables, and test reports you can keep for your records or leave with your customer.  Once the tests are created, plug in the cable, click test, and NetXpert XG starts testing the cable to IEEE 802.3 standards to prove the speed of your cable.  Not only do you get a wiremap and cable length, NetXpert XG tests BERT, SNR, Delay Skew, distance to opens, shorts, or miswires.  As a bonus you get active network tests for copper, fiber, and wireless.  And, with 2 NetXpert XG local units, you can test fiber cables.

Cable Project Qualifier

  • Use the project editor, cable test editor, test label editor to pre-configure your cable testing projects
  • Press test to automatically sequence up to 1000 cable tests from the local or remote device to increase cable testing efficiency when working alone
  • Test data cabling for IEEE 802.3 compliance at data rates up to 10 Gb/s (BERT)
  • Determine signal-to-noise ratio (SNR) for compliance up to 10 Gb/s
  • Measure delay skew for compliance up to 10Gb/s
  • Measure length of cable with TDR and capacitance measurements for highly accurate test results and easier troubleshooting
  • Full-color wire map shows distance to open, distance to short, miswires, split pairs, and shield on a color graphical display
  • Save test results and generate standards-based measurement reports providing “Pass/Fail” indication in pdf, csv, or xml format

Perform active network management

  • Support for IPv4 and IPv6
  • Discover your network and see the connected network devices
  • Identifies defective PoE switches with a PoE load test
  • DHCP test
  • Ping lists can be defined and saved for later use
  • LLDP/CDP detection and analysis
  • Identifies VLANs present in your network
  • Data transfer from the tester to the PC using USB stick, wireless, or bluetooth connectivity
Length Measurement Technology Time-Domain Reflectometry (TDR) and capacitance
Cable Measurements Cable Testing and ID: up to 1,000 ft (305 m)
Split Pair Detection: 3 ft (1 m) to 1,000 ft (305 m)
Length Measurement: 0 to 1,500 ft (457 m), ± (5%+1ft (30 cm))
Distance to fault: 0 to 656 ft (200 m) ± (5% + 3ft (1m))
Supports 8 wiremap remotes (RJ 45) and 24 RJ-45 ID only
remotes
Power over Ethernet (PoE) Test supports IEEE 802.3af PoE (Type 1, max 15.4W),
IEEE 802.3at PoE+ (Type 2, 30W) and 802.3bt PoE++ (Type 3, 60W)
Future proofed for IEEE 802.3bt Type 4 100W higherpower PoE
Active Ethernet Network and test support by interface:
Copper RJ-45 interface –100/1,000/2,500/5,000/10,000 Mb/sec link speeds
Fiber SFP+ #1 interface supports 10Gb/sec link speed
Fiber SFP+ #2 interface supports 1Gb/sec link speed
WiFi 802.11 a/b/g/n 2.4 Ghz WiFi and Bluetooth
Maximum Voltages Maximum voltage that can be applied to any 2 connector pins without causing damage to the tester:
RJ-45: 60 VDC or 50 VAC
Save Test Results Stores virtually unlimited cable or network tests with user defined names per project
Tone Generation Tone Frequencies: 730 Hz and 1440 Hz
Languages English, German, French, Spanish
Battery Li-Ion, 7.2 VDC, 3.1A-hr (typical)
Battery Life at 10Gb: 5 hrs minimum, 24 hrs stand-by
Temperature Operating: 14 to 140° F (-10 to 60°C)
Storage: -22 to 158°F (-30 to 70°)
Humidity 10 to 90% non-condensing
Enclosure Injection molded plastic
Display 7″ Color TFT-LCD capacitive touch display,
1024 x 600 resolution (WSVGA)
Size 245 x 177 x 73 mm (main unit)
130 x 177 x 55 mm (Active Remote)
Weight with Battery 2.6lbs (1.2 kg) main unit
1.3lbs (0.6 kg) Active Remote

datacheck analyzer software product bundle for mobile industrial ethernet diagnostics

Analyzer IE & Analyzer PRO

Software for Mobile Diagnostics and Acceptance Testing of Industrial Networks

Analyzer IE / PRO is a comprehensive software solution for acceptance testing and efficient troubleshooting of Ethernet-based industrial communication. In a PROFINET environment, the mobile diagnostic tool generates standardized acceptance reports in accordance with the recommendations of PROFIBUS & PROFINET International (PI), making it an easy-to-use product that is tailored to the needs of plant suppliers, maintenance personnel as well as service providers.

This product belongs to our PROFINET Diagnostics family. In order to view our expertise and the complete list of products please Download the PROFINET Diagnostics Brochure.

Comprehensive Functionality

  • Diagnostics list, error statistics, network statistics
  • Enhanced flexibility by supporting online as well as offline mode
  • Generation, analysis and handling of diagnostic data such as graphical topology, inventory list and reference measurements, also for standard Ethernet components (eg PCs, camera systems)

Automated Generation of Acceptance Test Documents

  • Time saving by automatically created test reports
  • Flexible definition of acceptance criteria
  • Transparent reporting by following PI guidelines

Tool Addressing Complete Plant Lifecycle

  • Data on network configuration, network communication and diagnostic messages
  • Error identification for effective troubleshooting (e.g. based on inventory list of network devices)
  • Chance to support exchange of general project information between end users, EPC contractors, system integrators and maintenance service providers
  • Seamless integration with Softing diagnostics per-manent monitoring solutions TH SCOPE and TH LINK
Technical Data
Functionality
  • Analysis of device logs
  • Live list, statistics, inventory
  • Topology and trend analysis
  • GSDML file support, plaintext messages in diagnostic list
  • Acceptance measurements and acceptance reports
  • Reference comparison
  • Configurable time intervals for automated export of inventory and topology data
  • Data export via Excel
  • Configurable Blacklist feature for robust operation
  • Optional (Analyzer PRO): Telegram analysis: jitter, refresh interval, load ratio
Supported Protocols PROFINET, EtherNet/IP, Modbus TCP
Interfaces
  • SNMP Agent
  • OPC UA Server
System Requirements Adobe Reader 8 or higher for reading the documentation and for printing the topology
Supported Operating Systems Windows 7, Windows 8.1, Windows 10
Windows Server 2012, Windows Server 2012 R2, Windows Server 2016
Network Access Data collection through TH LINK PC (PROFINET, EtherNet/IP, Modbus TCP)
Demo Version Full TH SCOPE functionality can be used for free for 30 days after installation
Licensing Software or hardware key
Scope of Delivery
Software Analyzer IE
License Software key (bound to PC) or hardware key
Hardware profiTap: Network tap for telegram analysis operation, optional (Analyzer PRO)
Documentation Installation manual, user manual, release note
Order Numbers
LRA-JY-003041 Analyzer IE (software key)
LRL-JY-003042 Analyzer IE (hardware key)
KPL-JY-003043 Analyzer PRO
Additional Products and Services
GEA-JN-003006 TH LINK PROFIBUS
GDA-JA-003034 TH LINK PROFINET
GDA-JY-003037 TH LINK Industrial Ethernet
LRA-JY-003028 TH LINK PC Industrial Ethernet
TRA-PB-TECH Training “PROFIBUS Technology”
TRA-PB-TS Training “PROFIBUS Troubleshooting with exam to Certified PROFIBUS Installer”
TRA-PN-CERTINST Training “PROFINET Acceptance and Commissioning”
TRA-PN-CERTENG Training “PROFINET Technology graduated as Certified PROFINET Engineer”
TRA-PN-TOOLS On-site training: PROFINET tools

Please contact us

People interested in this product, may be interested in :

 

THScope

Management and Diagnostics for Industrial Networks

TH SCOPE is a software product for industrial network management and network diagnostics. Geared to plant operators and maintenance personnel, TH SCOPE is an all-in-one, easy-to-use solution for permanent monitoring and predictive maintenance, for acceptance testing and for troubleshooting. Combined with TH LINK components, the product supports PROFIBUS, PROFINET, EtherNet/IP and Modbus TCP protocols.
The PROFINET Commissioning Report functionality is now available in new THSCOPE Release. Download the new THSCOPE under ‘Downloads’ section.

Comprehensive Presentation and Evaluation of Diagnostic Data

  • Provision of data on network communication, network configuration and diagnostic messages
  • Preparation of standardized exports (e.g. for acceptance testing)
  • Support of PROFIBUS, PROFINET, EtherNet/IP and Modbus TCP in combination with TH LINK components
  • Data acquisition also from standard Ethernet devices (e.g. PCs or camera systems)

Versatile solution for a wide range of diagnostic applications

  • Permanent monitoring and alerting
  • Commissioning and acceptance
  • Network documentation
  • Network and Plant Asset Management
  • Fault localization and identification

Flexible System and Process Integration

  • Web-based access, local or remote
  • Integration of inventory data into monitoring tools and process control systems via OPC UA
  • Export of diagnostic data for further processing in other applications (e.g. MS Excel)
  • Easy data exchange with Softing‘s Analyzer IE software (e.g. export of reference measurement)
  • Intuitive handling and operation
Technical Data
Functionality
  • Network overview with network and device status plus diagnostic messages with troubleshooting recommendations
  • Analysis of device logs
  • Live list, statistics, inventory
  • GSDML file support, plaintext messages in diagnostic list
  • Topology and trend analysis
  • Automatic e-mail notification in case of fault
  • Reference comparison
  • Acceptance measurements and acceptance reports
  • Configurable time intervals for automated export of inventory and topology data
  • Data export via Excel
  • Output of inventory data via OPC UA
Supported Protocols PROFINET, PROFIBUS, EtherNet/IP, Modbus TCP
Interfaces
  • SNMP Agent
  • OPC UA-Server
  • OPC Classic DA-Server
System Requirements
  • Web browser with Adobe Flash Player 14 or higher
  • Adobe Reader 8 or higher for reading the documentation and for printing the topology
Supported Operating Systems Windows 7, Windows 8.1, Windows 10
Windows Server 2012, Windows Server 2012 R2, Windows Server 2016
Network Access Data collection through TH LINK (PROFIBUS, PROFINET, EtherNet/IP, Modbus TCP und Industrial Ethernet)
Demoversion Full TH SCOPE functionality can be used for free for 30 days after installation
Licensing Via software or hardware key
Scope of Delivery
Software TH SCOPE (by download from Softing‘s website industrial.softing.com)
License Software or hardware key
Documentation Installation Manual, User Manual, Release Note
Order Numbers
LRA-JY-003024 TH SCOPE (software key)
LRL-JY-003025 TH SCOPE (hardware key)
Additional Products and Services
GEA-JN-003006 TH LINK PROFIBUS
GDA-JA-003034 TH LINK PROFINET
GDA-JY-003037 TH LINK Industrial Ethernet
LRA-JY-003028 TH LINK PC Industrial Ethernet

TH SCOPE:
If your network is protected by a second firewall in addition to the Windows firewall, make sure that the following settings are made to allow TH SCOPE services to communicate properly.

  • Enabling of HTTP port 80 – inbound and outbound
  • Enabling of SNMP port 161 inbound or port 2367 (if port 161 is used by another SNMP agent).
  • Enabling of IP 224.0.5.128 port 2364 UDP outbound
  • Enabling of UDP ports 2365 outbound and 2366 inbound

 

The following ports are used by TH SCOPE for internal communication only:

  • Port 22
  • Port 80
  • Port 1100
  • Ports 1123 – 1151
  • Port 1500
  • Port 1501
  • Ports 2363 – 2366
  • Ports 49152 – 49171

I am text block. Click edit button to change this text. Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.

People interested in this product, can be interested in :

THLink Industrial Ethernet

Industrial Ethernet Network Diagnostics Independent from Controller and Control Room

The TH LINK Industrial Ethernet diagnostics tool makes use of a controller-independent access to monitor PROFINET, EtherNet/IP and Modbus TCP networks. The diagnostic data is collected in networks comprising up to 254 nodes, and made available to users through the TH SCOPE software application. TH LINK Industrial Ethernet is easy to use and can be integrated without interfering with the operation of existing installations.

csm_THLink_IE_D_EN_170101_311_fbdb7e6c27

Independent Access to PROFINET, EtherNet/IP and Modbus TCP Networks

  • Controller-independent
  • Independent of configuration tools
  • Only one tool needed to monitor multiple IP subnetworks (up to 254 nodes, one or more controllers

Designed for Installation without Interference with Plant Operation

  • Connection to free port in industrial network, also possible during operation of the plant
  • No need to install TAPs or use mirror ports
  • Highest security (separate accesses for control room level and plant level, no routing)
  • Easy integration into existing plants thanks to compact design

Powerful Data Collection Capabilities Optimized for Ethernet-Based Industrial Communication

  • Support of the PROFINET, EtherNet/IP and Modbus TCP protocols
  • Collection also from standard Ethernet devices (e.g. PCs or camera systems)
  • PROFINET supervisor in PROFINET networks
  • Network load limit according to PROFINET guidelines

Optimized for Use by Maintenance Engineers

  • Suitable for network acceptance testing, continuous monitoring and troubleshooting
  • Easy and intuitive handling and operation
  • Fault identification with intelligent troubleshooting assistance
  • Seamless integration with TH SCOPE diagnostics software
Functionality
  • Network detection and data collection
  • Alarm notification in case of fault
  • Basic monitoring, configuration
  • Integrated web server
Input Voltage 24 VDC (18 VDC … 32 VDC)
Current consumption max. 180 mA
Current consumption relay contact max. 100 mA
Operating Temperature -40 °C … +75 °C
Relative Air Humidity 5 … 95 % (no condensation)
Ethernet Ports RJ-45 (10Base-T/100Base-TX)
Supported SD Cards See Release Notes
Mounting 35 mm DIN rail
Dimensions (HxWxD) 22.5 x 99 x 114.5 mm
Weight 120 g
Certifications CE
GDA-JY-003037 TH LINK Industrial Ethernet

Scope of Delivery

Hardware TH LINK Industrial Ethernet
Documentation Installation Manual, Release Note (by download)

Additional Products and Services

ATV-LRA-JY-003024 TH SCOPE (software key)
ATV-LRL-JY-003025 TH SCOPE (hardware key)
ATV-LRA-JY-003028 TH LINK PC Industrial Ethernet (software key)
ATV-LRL-JY-003029 TH LINK PC Industrial Ethernet (hardware key)
ATV-TRA-PN-TECH Training “PROFINET Technology”
ATV-TRA-PN-CERTENG Training “PROFINET Commissioning and Troubleshooting”

THLink – PROFINET

THLink Profinet

PROFINET Diagnostics Independent from Controller and Control Room

The TH LINK PROFINET diagnostics tool makes use of a controller-independent access to monitor PROFINET networks. The diagnostic data is collected in networks comprising up to 254 nodes, and made available to users through the TH SCOPE software application. TH LINK PROFINET is easy to use and can be integrated without interfering with the operation of existing installations.

Independent Access to PROFINET Network

  • Controller-independent
  • Independent of configuration tools
  • Only one tool needed to monitor multiple IP subnetworks (up to 254 nodes, one or more controllers)

Designed for Installation without Interference with Plant Operation

  • Connection to free port in PROFINET network, also possible during operation of the plant
  • No need to install TAPs or use mirror ports
  • Highest security (separate accesses for control room level and plant level, no routing)
  • Easy integration into existing plants thanks to compact design

Powerful Data Collection Capabilities Optimized for PROFINET

  • Collection from PROFINET devices and other nodes (e.g. PCs or camera systems)
  • PROFINET supervisor in PROFINET networks
  • Network load limit according to PROFINET guidelines

Optimized for Use by Maintenance Engineers

  • Suitable for network acceptance testing, continuous monitoring and troubleshooting
  • Easy and intuitive handling and operation
  • Fault identification with intelligent troubleshooting assistance
  • Seamless integration with TH SCOPE diagnostics software
Functionality
  • Network detection and data collection (active/passive for PROFINET Networks)
  • Alarm notification in case of fault
  • Basic monitoring, configuration
  • Integrated web server
Input Voltage 24 VDC (18 VDC … 32 VDC)
Current consumption max. 180 mA
Current consumption relay contact max. 100 mA
Operating Temperature -40 °C … +75 °C
Relative Air Humidity 5 … 95 % (no condensation)
Ethernet Ports RJ-45 (10Base-T/100Base-TX)
Supported SD Cards See Release Notes
Mounting 35 mm DIN rail
Dimensions (HxWxD) 22.5 x 99 x 114.5 mm
Weight 120 g
Certifications CE
GDA-JA-003034 TH LINK PROFINET

Scope of Delivery

Hardware TH LINK PROFINET
Documentation Installation Manual, Release Note (by download)

Additional Products and Services

LRA-JY-003024 TH SCOPE (software key)
LRL-JY-003025 TH SCOPE (hardware key)
LRA-JY-003028 TH LINK PC Industrial Ethernet (software key)
LRL-JY-003029 TH LINK PC Industrial Ethernet (hardware key)
GDA-JY-003037 TH LINK Industrial Ethernet
TRA-PN-TECH Training “PROFINET Technology”
TRA-PN-CERTENG Training “PROFINET Commissioning and Troubleshooting”

TH LINK:
enablement of the following ports:

  • HTTP Protocol:      80 TCP
  • Firmware update: 1100 TCP
  • communication with each other:    1123, 1124, 2364 UDP
  • communication with TH SCOPE via Multicast:  2364 UDP
  • communication with TH SCOPE via Unicast:    1151, 2365 UDP

There must be no firewall between the TH LINK and the PROFINET and/or EtherNet/IP devices.

TH SCOPE:
If your network is protected by a second firewall in addition to the Windows firewall, make sure that the following settings are made to allow TH SCOPE services to communicate properly.

  • Enabling of HTTP port 80 – inbound and outbound
  • Enabling of SNMP port 161 inbound or port 2367 (if port 161 is used by another SNMP agent).
  • Enabling of IP 224.0.5.128 port 2364 UDP outbound
  • Enabling of UDP ports 2365 outbound and 2366 inbound

 

The following ports are used by TH SCOPE for internal communication only:

  • Port 22
  • Port 80
  • Port 1100
  • Ports 1123 – 1151
  • Port 1500
  • Port 1501
  • Ports 2363 – 2366
  • Ports 49152 – 49171